Regency Wraps P36-LPG4 Manual Do Utilizador

Página de 44
Regency
®
 P36-4 Gas Log Fireplace
33
MAINTENANCE
3)  Check for evidences of excessive 
condensation, such as water droplets forming 
in the inner liner, and subsequently dripping 
out the joints, Continuous condensation can 
cause corrosion of caps, pipe, and fi ttings. 
It may be caused by having excessive 
lateral runs, too many elbows, and exterior 
portions of the system being exposed to 
cold weather.
4)  Inspect joints, to verify that no pipe 
sections or fi ttings have been disturbed, 
and consequently loosened. Also check 
mechanical supports such as Wall Straps, 
or plumbers' tape for rigidity.
GOLD-PLATED & 
BRASS
LOUVRES OR TRIM
The 24 carat gold plated or brass fi nish on the 
trim requires little maintenance, and need only 
be cleaned with a damp cloth. DO NOT use 
abrasive materials or chemical cleaners, as 
they may harm the fi nish and void the warranty. 
Clean any fi ngerprints off  before turning the 
unit on.   If the top louvres start to discolour, 
check the door gasket seal and replace if 
necessary.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the gas valve and allow the unit to cool 
before opening door and carefully remove the 
logs. (The pilot light generates enough heat to 
burn someone.) If for any reason a log should 
need replacement, you must use the proper 
replacement log. The position of these logs 
must be as shown in the diagrams under Log 
Installation.
Note:  Improper  positioning of logs may 
create carbon build-up and will 
severely alter the unit's performance 
w h i c h   i s   n o t   c o v e r e d   u n d e r 
warranty.
THERMOPILE / 
THERMOCOUPLE
1)  Open the bottom louvres.
2)  Loosen the thermocouple or thermopile with 
a 7/16" spanner.
3)  Disconnect thermocouple by loosening 
nut from the valve with a 9mm spanner. 
Disconnect thermopile by loosening 2 
screws marked TP on the valve.
4)  Drop the thermocouple or thermopile down 
from the bracket and pull it out of the unit.
5)  Reinstall the new ones in reverse order.
GLASS GASKET
 
If the glass gasket requires replacement use 
5/8" fl at glass gasket for the Bay Front (Part 
# 936-243) and a tadpole glass gasket for the 
Flush Front (Part # 936-155).   
DOOR GLASS
Your Regency
®
 fi replace is supplied with high 
temperature, 5 mm Neoceram ceramic glass that 
will withstand the highest heat that your unit will 
produce.   If your glass requires cleaning, we 
recommend using an approved glass cleaner 
available at all authorized dealers. Do not use 
abrasive materials. Do not clean the glass 
when hot.
In the event that you break your glass by impact, 
purchase your replacement from an authorized 
Regency
®
 dealer only, and follow our step-by-
step instructions for replacement.
WARNING: Do not operate the 
appliance with the glass panels 
removed, cracked or broken. 
Replacement of the glass  panels 
should be done by a licensed or 
qualifi ed service person.
Caution:  Wear gloves when 
removing damaged or broken 
glass.
Flush Glass Replacement
Remove the fl ush door front (as per instructions  
in section "Standard Flush Door"). Remove 
the 4 glass clips from each corner. Slide in the 
new replacement glass. Push the 4 glass clips 
back onto the frame.  The glass must have 
gasketing around it.
Bay Glass Replacement
1)  Remove the door from the unit and place 
on a soft surface to prevent scratching.
2)  Remove the nuts holding the glass clips in 
place and remove.
3)   Replace the glass. The glass must have 
gasketing around it.
5)  Reverse the previous steps, replace the glass 
clips and fasten with the nuts but do not over 
tighten, as this can break the glass.
6)  Replace door on the stove and check the 
seal.