Hearth & Home Technologies CL36D Manual Do Utilizador

Página de 32
02-02
15
12538 Rev D
CL36D AND CR36D INSTALLATION INSTRUCTIONS
F. INSTALLATION OF FIREPLACE
WARNING!
Before starting, do the following:
1. Wear gloves and safety glasses for protection.
2. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure.
3. Always maintain the minimum air space required to the enclosure to prevent fire.
Important: To ensure proper fit of the glass doors,
check  the  fireplace  opening  for  square.  Measure
diagonal  distances  of  the  opening  to  make  sure
they  are  equal.  If  they  are  not  equal,  continue  to
shim the fireplace until those diagonals are equal.
Figure 7 - Positioning the Metal Strips
1. Positioning the Fireplace
This fireplace may be placed on either a combustible
or noncombustible continuous flat surface. Follow the
instructions  for  framing  on  pages  10-12.  Slide  the
fireplace  into  position.  Be  sure  to  provide  the
minimum ½” air clearance at the sides and back of
the fireplace assembly.
2. Placing the Protective Metal Hearth
Strips
Included with your fireplace you will find three metal
hearth  strips  measuring  approximately  28”  x  4”.
These  strips  are  used  to  provide  added  protection
where the fireplace and the hearth extension meet.
Slide each metal strip 2” under the front edge of the
fireplace.  The  individual  pieces  must  overlap  each
other by 1” minimum in the middle of the fireplace to
provide continuous coverage of the floor. See Figure 7.
These metal strips should extend from the front and
sides of the fireplace opening by 2”.
3. Leveling the Fireplace
Level  the  fireplace  side-to-side  and  front-to-back.
Shim  with  noncombustible  material,  such  as  sheet
metal, as necessary. Secure the fireplace (using the
nailing flanges located on either side of the fireplace)
to the vertical framing.