Hearth & Home Technologies 830-0381 Manual Do Utilizador

Página de 28
3100-I ACT WOOD INSERT
Page 6
     September 1, 2008 
 250-6381D
AVOID FIRE:  To ensure that insulation or any other combustible 
material does not contact the chimney, a chimney inside the house 
must have at least 2 inches (51mm) of air space clearance around 
the chimney.  A chimney outside the house must have at least 1 
inch (5mm) clearance to the combustible structure.  Noncombus-
tible fire stops must be installed at the spaces where the chimney 
passes through floors and/or ceilings.  
Refer to Figures 8A & 8B 
on page 8.  Canadian installations require a full reline of the 
chimney
CHIMNEY HEIGHT/DRAFT
T
o be sure that your Quadra-Fire insert burns properly, the chimney 
draft (static pressure) should be approximately -0.10” water column 
(W.C.)  during  a  high  burn  and  -0.04”  W.C.  during  a  low  burn, 
measured 6” (152mm) above the top of the insert after one hour of 
operation at each burn setting.
NOTE:  These are guidelines  only, and  may vary somewhat  for 
individual installations.
Your  Quadra-Fire  insert  was  designed  for  and  tested  on  a  6” 
(152mm) chimney, 12 ft-14 ft (360-420cm) high, measured from 
the base of the insert.  The further your stack height or diameter 
varies  from  this  configuration,  the  possibility  of  performance 
problems increases.  In addition, exterior conditions such as roof 
line,  surrounding  trees,  prevailing  winds  and  nearby  hills  can 
influence insert’s performance.
A masonry chimney or a listed factory-built UL103 HT Class “A” 
chimney must be the required height above the roof and any other 
nearby obstructions.  The chimney must be at least 3 ft (91cm) higher 
than the highest point where it passes through the roof and at least 
2 ft (61cm) higher than the highest part of the roof or structure that 
is within 10 ft (305cm) of the chimney, measured horizontally.  
See 
2-10-3 Rule (Figure 6A).  These are safety requirements and are 
not meant to assure proper flue draft.
3 ft Min 
(91cm) 
2 ft Min (61cm) 
10 ft Min 
(305cm) 
2-10-3 RULE 
Figure 6A
NOTE: Clearances may only be reduced by means approved by 
the regulatory authority having jurisdiction.
WE  RECOMMEND  that  a  qualified  building  inspector  and  your 
insurance  company  representative  review  your  plans 
before 
installation.
INSTALLATION RECOMMENDATIONS
The  Quadra-Fire  3100-I  ACT  insert  has  met  and  surpassed  the 
most  stringent  emissions  standards  in  the  United  States.    The 
sophistication of the interior firebox design requires that a proper 
draft be supplied by the chimney, therefore adherence to the follow-
ing factors will enable your insert to operate at its optimum capabil-
ity.
REqUIRED:  A minimum starter pipe reaching to the base of the 
existing code approved masonry chimney and an airtight face seal, 
but a full chimney liner for factory-built fireplaces is recommended 
for USA and is required in Canada.
BETTER:  Direct connection to the first flue liner in accordance with 
the requirements of the NFPA 211.
BEST:    A  complete  relining  of  the  chimney  system  with  a  6  inch 
(152mm)  diameter  listed,  stainless  liner.    Required  for  factory-built 
fireplace installations in Canada, recommended in USA. The sections 
must  be  attached  to  the  insert  and  to  each  other  with  the  crimped 
(male) end pointing toward the insert.  See 
Figure 6B.   All joints, 
including  the  connection  at  the  flue  collar,  should  be  secured  with 
three sheet metal screws.  Make sure to follow the minimum clear-
ances to combustibles as set out on 
Page 5 of the manual.
These  installation  instructions  describe  the  installation  and 
operation  of  the  Quadra-Fire  3100-I ACT  Wood  Insert.    This 
insert  meets  the  U.S.  Environmental  Protection Agency’s  1990 
particulate  emission  standards.    The  3100-I ACTis  listed  by 
OMNI-Test  Laboratories,  Inc.  to  UL  Safety  Standard  1482,  and 
ULC S628, and (UM) 84-HUD. 
Check with your local building code agency before you begin your 
installation to ensure compliance with local codes, including the 
need for permits and follow-up inspections.  Be sure local building 
codes do not supersede UL specifications and always obtain a 
building  permit  so  that  insurance  protection  benefits  cannot  be 
unexpectedly  cancelled.    If  any  assistance  is  required  during 
installation, please contact your local dealer.