trouBlesHootING
Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two 
most common causes of a malfunctioning gas appliance are:
1.  Loose wiring connections
2.  Construction debris clogging the pilot and/or gas control valve filter
OBSERVED PROBLEM
Ignitor will not spark or pilot 
will not light
Pilot will not stay lit
POSSIBLE CAUSE
1. No  gas  supply,  or  shutoff 
valve is OFF
2. Air in gas line
3. Construction  debris  clog-
ging pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control  valve  knob  is  not 
opening
7. No  power  to  unit  or  the 
ignition  module  or  power 
transformer is bad
8. Vent  damper  not  fully 
open
1. Loose wiring on thermopile 
to regulator valve. No mil-
livolt current is being sent 
back to regulator
2. If  valve  knob  and  wall 
switch are in the ON posi-
tion,  probable  defective 
regulator valve
3. Vent  damper  not  fully 
open
REMEDY
1. Check  to  see  if  you  have 
gas supply and that equip-
ment  shutoff  valve  is 
opened
2. Repeat lighting procedure 
several  times  to  purge  all 
air out of lines. If after re-
peated attempts appliance 
does not light, call for quali-
fied service and repair.
3. Remove  debris  and  dirt, 
inspect and clean any other 
possible obstructions
4. Contact your gas supplier 
to check pressure
5. Have a qualified technician 
replace pilot line
6. Replace control valve (Re-
fer to Replacement Parts
page 20)
7. Check that main power is 
on and that all wire connec-
tions are made correctly to 
ignition model (see Wiring 
Diagram, page 21). Check 
for  24  VAC  at  secondary 
side  of  transformer.  If  24 
VAC is present, and mod-
ule does not operate, have 
module replaced, otherwise 
have transformer replaced
8. Open  vent  damper  until 
fully  locked  in  the  OPEN 
position
1. Check wiring connections. 
Refer  to  wiring  diagram 
shown  in  Wall  Switch  In-
stallation, page 11
2. Have a qualified technician 
replace valve
3. Open  vent  damper  until 
fully  locked  in  the  OPEN 
position