Outdoor model 
MUZ-GE25VA-
A1
MUZ-GE25VA-
A2
MUZ-GE25VAD
MUZ-GE33VA
Power supply 
Single phase, 230 V, 50 Hz
Capacity 
Rated frequency (Min.-Max.)
Cooling
kW
2.5 (1.1 - 3.5)
3.3(1.4 - 3.9)
Heating
3.2 (1.3 - 4.5)
3.2 (1.3 - 4.1)
3.2 (1.3 - 4.5)
4.0 (1.4 - 4.8)
Breaker Capacity
A
10
Electrical data
Power input  1 (Total)
Cooling 
W
560
910
Heating
730
1,030
Running current  1 
(Total)
Cooling
A
2.9
4.3
Heating 
3.8
4.8
Power factor  1 (Total)
Cooling
%
84
92
Heating
84
93
Starting current  1 (Total)
A
3.8
4.8
Coeffi cient of performance 
(COP)  1 (Total)
Cooling
4.46
3.63
Heating
4.38
3.88
Compressor
Model
KNB073FFDHC
KNB073FKVHC
KNB092FFAHC
Output
W
550
650
Current  1
Cooling
A
2.44
3.70
Heating
3.30
4.30
Refrigeration oil 
(Model)
L
0.32 (NEO22)
0.36 (NEO22)
0.32 (NEO22)
Fan motor
Model
RC0J50-DB
Current 1
Cooling
A
0.24
0.31
Heating
0.27
Dimensions W × H × D
mm
800 × 550 × 285
Weight
kg
30
Special remarks
Dehumidifi cation
Cooling
L/h
0.2
0.6
Air fl ow  1 
Cooling
High
m
3
/h
Med.
1,806
1,956
Low
1,170
1,806
Heating
High 
2,106
2,130
Med.
1,806
1,956
Low
1,452
1,476
Sound level  1
Cooling
dB(A)
46
47
Heating
48
Fan speed
Cooling
High
rpm
Med.
740
800
Low
490
740
Heating
High 
860
870
Med.
740
800
Low
600
610
Fan speed regulator
3
Refrigerant fi lling capacity 
(R410A)
kg
0.80
NOTE: Test conditions are based on AS/NZS 3823.1.1.
 
Cooling: Indoor 
Dry-bulb temperature 27°C  
Wet-bulb temperature   19°C
 
 
Outdoor  Dry-bulb temperature 35°C  
Wet-bulb temperature   (24°C)
 
Heating: Indoor 
Dry-bulb temperature 20°C  
Wet-bulb temperature  15.5°C
 
 
Outdoor  Dry-bulb temperature   7°C  
Wet-bulb temperature     6°C
 
Refrigerant piping length (one way): 5 m
 
1 Measured under rated operating frequency.