Heat Controller, Inc. 
INSTALLATION INSTRUCTIONS 
HDG Series Air Handler
20
Scroll Heat Pump Applications*
Air Handler:
Heat Pumps
Piston Size
HDG18FB-1A
HRG18S-1D
0.052 inch
HDG24FB-1A
HRG24S-1D
0.058 inch
HDG30FB-1A
HRG30S-1D
0.065 inch
HDG36FB-1A
HRG36S-1D
0.068 inch
HDG42FB-1A
HRG42S-1D
0.080 inch
HDG48FB-1A
HRG48S-1D
0.090 inch
HDG60FB-1A
HRG60S-1D
0.108 inch
Scroll Compressor Condenser Applications**
Air Handler:
Condeners
Piston Size
HDG18FB-1A
RSG18S-1D
0.052 inch
HDG24FB-1A
RSG24S-1D
0.058 inch
HDG30FB-1A
RSG30S-1D
0.065 inch
HDG36FB-1A
RSG36S-1D
0.073 inch
HDG42FB-1A
RSG42S-1D
0.077 inch
HDG48FB-1A
RSG48S-1D
0.105 inch
HDG60FB-1A
RSG60S-1D
0.097 inch
Rotary Compressor Condenser Applications**
Air Handler:
Condeners
Piston Size
HDG18FB-1A
RSG18R-1D
0.054 inch
HDG24FB-1A
RSG24R-1D
0.061 inch
HDG30FB-1A
RSG30R-1D
0.065 inch
*PISTON REQUIRED FOR THIS APPLICATION IS FACTORY INSTALLED.
**PISTON REQUIRED FOR THIS APPLICATION IS NOT FACTORY INSTALLED, REQUIRES
FIELD CONVERSION. 
Flowrator Piston Size Chart
NOTE: Pistons are factory installed for use with HRG-1D series heat pump. To use the 
coil with a RSG-1D series condenser, a piston change may be required. Refer to table below.