Mitsubishi PJZ012A087B Manual Do Utilizador

Página de 22
11
Press 
 LOUVER button once, and the current status of louver is displayed.
ADJUSTING WITH LOUVER BUTTON (Indoor unit with auto swing function)
 
HOW TO ADJUST THE LOUVER
 
< WIRED REMOTE CONTROL >
The display during 
auto swing
The display with the  
louver position fixed 
When you operate the swing louver
1.
  Press
 
 LOUVER button, and button the display to 
 ”.
The function of the swing louver 
during the heating preparation, 
heating/defrost
” or “Heating/Defrost” is 
displayed, the position of the swing louver is 
automatically switched to horizontal.
When the operation is switched to normal after “The heating 
preparation” or “Heating/Defrost” ends, the position of swing louver 
returns to that of setting.
When the position of the swing louver is fixed
1.
 Press
 
 LOUVER button once while the louver 
is swinging, and 4 stop positions are displayed every 
one second in order.
 
 ↔ 
 ↔ 
 ↔ 
2.
 Press
 
 LOUVER button once when the display 
of the louver comes to the position you desire.
 
The display is switched to stop, and the position of louver is fixed.
Recommended louver fixed position
COOL•DRY 
HEAT
horizontal position
Stop the air conditioner and press 
 SET 
button and 
 LOUVER button simultaneously 
for three seconds or more.
The following is displayed if the number of the indoor units 
connected to the remote control is one. Go to step 
4
.
È
The following is displayed if the number of the indoor units 
connected to the remote control are more than one
È
Press 
 or  button.(selection of indoor unit)
Select the indoor unit of which the louver is set.
[EXAMPLE]
⇔“
⇔“
Press 
 SET button. (determination of 
indoor unit)
Selected indoor unit is fixed.
[EXAMPLE]
” (lit for two seconds)
È
È
Press 
 or  button. (selection of louver No.)
Select the louver No. to be set according to the left figure.
[EXAMPLE]
” 
⇔ “
” 
⇔ “
” 
⇔ 
Note :  For FDE and FDK, select “
”. For FDFW, select 
”. Other louver No. settings have no effect.
Press 
 SET button. (Determination of 
louver No.)
The louver No. to be set is confirmed and the display shows the 
upper limit of the movable range.
[EXAMPLE]  If No.1 louver is selected,
” 
←current upper limit position
Press 
 or  button. (selection of upper limit 
position)
Select the upper limit of louver movable range.
“position 1” is the most horizontal, and “position 6” is the most 
downwards.
“position --” is to return to the factory setting. If you need to change 
the setting to the factory setting, use “position --”.
” (The most horizontal)
⇔ “
⇔ “
⇔ “
⇔ “
⇔ “
” (The most downward)
⇔ “
” (Return to the position of shipment)
2•4•6•8 1 
10 
3•5•7•9 
 
HOW TO SET THE AIRFLOW DIRECTION 
(IN CASE OF FDT, FDTC, FDE, FDK, FDFW) <WIRED REMOTE CONTROL>
No. 4
No. 2
No. 1
No. 3
Control bo
x
Piping side
Drain hose side
Louver No.
[for FDT]
It is possible to change the movable range of the louver on the air outlet from the wired remote control. Once the top and bottom position is 
set, the louver will swing within the range between the top and the bottom when swing operation is chosen.
With Ceiling cassete −4 way − FDT and FDTC, it is also possible to apply different setting to each louver.
NOTICE
•  For FDT and FDTC type, in case the 
louver No. to be set is uncertain, set 
any louver temporarily. The louver 
will swing once when the setting 
is completed and it is possible to 
confirm the louver No. and the 
position.
After that, choose the correct louver 
No. and set the top and bottom 
position.
• 
For FDE and FDK type, set louver 
No. 1.
  For FDFW type, set louver No. 2.
Other settings selected have no 
effect.
(downwards)
(upward)
the position of the louver
Press 
Press 
NOTICE 
•  Do not move the swing louver forcibly by hands for fear that it may be damaged.
•  Do not blow downwards during cooling operation for a long time for fear that dew condensation may be formed at the side panel. 
(In 
case of FDE)
No.2
No.1
No.3
No.4
Control box
Drain hose side
Piping side
Louver No.
[for FDTC]
(upward)
PJZ012A087B.indd   11
PJZ012A087B.indd   11
2014-3-4   10:28:39
2014-3-4   10:28:39