Mitsubishi PJZ012A087B Manual Do Utilizador

Página de 22
17
 
HOW TO MAINTAIN
 Ceiling cassette −4 way Compact (600 x 600 mm)− (FDTC)
1. Slide the inlet grille levers in the direction of the 
arrow (
), and open it downwards.
2.  Turn the inlet grille stopper.
3.  Pull the filter toward you.
4.  When the filter is put in place, insert the filter into 
the hooks on the inlet grille, and be sure to return 
the stopper to its original position.
5.  When putting the inlet grille back in place, slide the 
levers in the opposite direction and check to be 
sure that the grille does not come open.
Hooks
Hooks
Stopper
 
HOW TO MAINTAIN
Air filter is attached when the air conditioner is installed, so consult your dealer about how to remove or clean it.
 Duct connected −High static pressure− (FDU)
 Duct connected −Middle static pressure− (FDUM)
 Duct connected (Ultra thin) −Low static pressure− (FDQS)
 Duct connected −Compact & Flexible− (FDUH)
 Duct connected −High static pressure Out door Air processing unit (FDU -F)
 Duct connected −Low static pressure− (FDUT)
 Floor standing -2way- (FDFW)
 
<How to open, close the inlet panel>
 
Open
Place fingers at the recesses on both sides of the panel 
and pull down the panel forward so that it will be open by 
about 15°.
 Close
Push both ends evenly and press further lightly at the 
center.
 Ceiling cassette −1 way− (FDTS)
1.  Slide the lever of the suction grille in the arrow (
) direction 
to open the grille.
2.  While light pushing up, remove the filter from the tabs at the 
left and righit, and pull towards the front
.
 Ceiling cassette −1 way compact− (FDTQ)
1.  Slide the lever of the suction grille in the arrow (
) direction 
to open the grille.
2.  While light pushing up, remove the filter from the tabs at the 
left and righit, and pull towards the front
.
Air filter
Tab
Suction grille
Tabs
Air filter
Tab
Suction grille
Tabs
 
<How to remove, install the inlet panel>
 
Remove
When removing the panel for internal cleaning or others, 
open the panel, remove the string and then pull it forward.
 Install
Secure the upper edge of the panel by lightly pushing it 
in, place the string as illustrated and then close the panel.
 
<How to remove, install the filter>
 
Remove
1. Pull up the air inlet panel forwards.
2. Lightly hold the knobs at the both sides and lift a little to 
remove the panel forward.
 
Install
1. Hold firmly the filter at the both sides as shown at right 
and insert securely.
2. Close the air inlet panel.
 Floor standing (with casing) (FDFL)
Remove the front panel and pull the air filter out from the 
bottom of the unit.
 Floor standing (without casing) (FDFU)
Pull the air filter out from the bottom of the unit.
 Wall mounted (FDK)
1.  Pull up the suction grille forward.
 
Hold the concave sections at both the righit and left side 
with your hands and pull the suction grille forward.
 
It stops while being open at about 60
°
.
2.  Lightly hold the handle of the air filter , slightly lift it upward, 
and then pull it out forward.
 
When mounting, press the lever forward untill it snaps.
 
When morrting, snab the filter into the tabs of inlet grille.
 Ceiling suspended (FDE)
1.  Slide the lever of the inlet grille backward (
 direction) and 
open it downwards.
2.  Pressing the inlet grille, press the filter to remove it from the 
tab and pull it 
downwards.
Air filter
tabs
 Ceiling cassette −2 way− (FDTW)
1.  Push one side of the inlet panel (pin A side) upward.
2.  Disengage the panel from pin A.
3.  Disengage the panel from the pin B and remove the panel.
4.  Press the air filter and turn the stopper to remove the air 
filter.
e Disengage the pin B side.
c Push the pin A side upward.
d Disengage the pin A side.
Pin B         Pin A
Panel
Stopper
Number of stoppers
FDTW 28 - 71     6pc.
FDTW 90-140     10pc.
Caution 
Install the air filter in the correct order.
Turn
PJZ012A087B.indd   17
PJZ012A087B.indd   17
2014-3-4   10:28:42
2014-3-4   10:28:42