Mitsubishi PSA012B790 Manual Do Utilizador

Página de 24
12
Press 
 SET button (Fixing of the upper 
limit position)
The upper limit position is fixed and the setting position is 
displayed for two seconds. Then proceed to lower limit position 
selection display.
[EXAMPLE]
” (lights for two seconds)
” (shows current setting)
Press 
 or  button (Selection of lower limit 
position)
Select the lower limit position of louver.
“position 1” is the most horizontal, and “position 6” is the most 
downwards.
“position  --” is to return to the factory setting. If you need to 
change the setting to the factory setting, use “position --”. 
” (the most horizontal)
 “
 “
 “
 “
 “
” (the most downwards)
 “
” (return to the position of shipment)
Press 
 SET button (Fixing of the lower limit 
position)
The upper limit position and lower limit position are fixed, the set 
positions lights for two seconds, and then the setting is completed.
•  After the setting is completed, the louver which was set 
moves from the original position to the lower limit position, 
and goes back to the original position again. (This operation 
is not performed if the indoor unit and/or indoor unit fan is in 
operation.)
[Example]
” (lights for two seconds)
10
 Press 
 button.
Louver adjusting mode ends and returns to the original display.
 
HOW TO SET THE AIR FLOW DIRECTION 
< WIRED REMOTE CONTROL >
NOTICE
(downwards)
(horizontal)
the position of the louver
[EXAMPLE]  For Upper position 2, Lower position 6
Lower 
position
Movable 
range
Upper 
position
•  When plural remote controllers are connected, louver position setting cannot be set by slave remote control.
•  If you press
 
 RESET button during settings, the display will return to previous display. If you press 
 
button during settings, the mode will end and the original display will return, and the settings that have not been 
completed will become invalid.
Note :  If the upper limit position number and the lower limit 
position number are set to the same position, the louver 
is fixed at that position. And auto swing does not function.
Clean the filter frequently
 
 See page 16
If the filter is clogged…
•  The cooling/heating capacity will get reduced. Moreover it leads 
to waste of electricity and larger operation noise.
•  It may cause failure.
•  Dew may form and drop during cooling.
Do not block the inlet and outlet grilles of the 
indoor and outdoor units.
Excessive load to the unit may cause failure.
Keep moderate room temperature
Too much cooling or heating is not good for your health. It will also 
waste the electricity.
Block direct sunlight and prevent draft
Block direct sunlight with blinds and curtains during cooling. Close 
the windows and doors except when ventilation is necessary.
Adjust the airflow properly
Do not expose yourself directly to the airflow for too long time. For 
small animals and plants, it is harmful as well.
If you feel cold underneath your feet during heating
If the ceiling is so high that the warm airflow does not circulate 
underneath your feet, it is recommended to use a circulator. 
Consult your dealer for more detail.
Stop the operation and turn the power supply 
off if there are any possibility of lightning 
strikes during a thunderstorm.
Lightning strikes may lead to the failure of air-conditioning system.
 
FOR COMFORTABLE USE
The filter should be cleaned when 
the “Filter cleaning” message 
is displayed, and at the ends of 
cooling and heating seasons.
 
HOW TO OPERATE VENTILATION 
(WHEN A VENTILATOR IS INSTALLED) 
< WIRED REMOTE CONTROL >
Press 
 
VENTI button.
” is displayed, and the ventilation operation begins.
Stop
 Press 
 VENTI button again.
When the ventilator is set to “NO VENTI LINK”, the ventilator can be turned on and off independently regardless 
of the operation of the air conditioner.
When the ventilator is set to “VENTI LINK”, the ventilator operation will be interlocked with the air conditioner 
operation.
NOTICE
  If no ventilator is connected, no operation can be performed by 
pressing the ventilation button. (“
” is displayed).
VENTILATION OPERATION NOT LINKED WITH UNIT’S 
OPERATION
Press 
 button.
If a ventilator is connected, ventilation will operate automatically.
” is displayed.
Stop
 Press 
 button again.
NOTICE
•  No operation can be performed by pressing the ventilation button. 
(“
” is displayed).
VENTILATION OPERATION LINKED WITH UNIT’S OPERATION