Problem Solving Guide
Problem Solving Guide
Frequently Asked Questions
Q: I turned the heater on, but nothing is happening yet.
A:  Make sure the heater temperature is set above your room’s current temperature on the 
thermostat dial. After 2 minutes the air inside the heater will be warm and the heater fan 
will begin to operate. 
Q: Why is the heater still running after I turned down the thermostat?
A:  You will hear the heater fan running after you have turned the thermostat down. This 
allows the heater to cycle the remaining heat into the room and helps to cool down the 
heating element which protects the unit’s components from overheating.  
Q: Can I use the heater to heat multiple rooms at the same time?
A:  The heating capability will depend on your floor plan, the insulation and the room size. 
Ceiling fans will help circulate heat. Placing the heater in a central location will also help 
move heat between rooms.
Q: Will my heater work in areas without insulation?
A:   The heater will work in garages, basements and unfinished rooms. However, bear in 
mind the effectiveness of your heater depends on how well the area is sealed and 
insulated. As with any heater, the better the walls, floor and ceiling are sealed and 
insulated, the more effective the room will be heated.
Q: Can I use multiple heaters in an area?
A:  Depending on the size of the area, you may wish to use multiple heaters. Multiple 
heaters may be used. Your heater is rated 12 amps so each heater must plug into an 
independent 15 amps or greater circuit.
Any other service should be done by an Authorized Service Representative.
Service 1-888-6-RICCAR 
To locate your nearest retailer, visit our website at 
www.riccar.com 
The zone heater’s airflow 
has been reduced.
The zone heater stays on 
after I turn the thermostat 
down.
The zone heater will not  
turn on.
The circuit breaker  
button popped out.
The zone heater tipped 
over on its side and shut 
off, but the fan is still 
running.
The programmable 
thermostat doesn’t light up.
Problem  
• Make sure the filter is clean.
• Check the back intake for any objects that could obstruct airflow.
•  If the heater’s airflow is still diminished or has stopped, contact your 
Riccar Authorized Retailer.
•  This is a normal function of the heater. During this time, the heater is 
cycling the remaining heat into the room and is cooling the heating ele-
ment down.
•  Make sure the heater is plugged directly into an unused, grounded 120 
volt, 15 amps or higher circuit receptacle.
•  Make sure the amber light displays on the front of the unit indicating 
the heater is plugged into an electrical outlet, turned on and is receiving 
power.
•  Make sure the heater temperature is set above your room’s  
current temperature
• Press the on/off switch to Off.
•   Unplug the power cord.
•  Push the circuit breaker button to reset.
•  Plug the power cord directly into an unused, grounded 120 volt, 15 
amps or higher circuit receptacle.
• Press the on/off switch to On.
•  If the circuit breaker trips a second time, return the heater to an 
Authorized Riccar Retailer.
•  This is a normal safeguard function of the heater. Return the heater to 
its normal upright operating position and the power will resume.
• Slide the On/Standby switch to On.
Possible Solution
Troubleshooting