Maintenance/Service
•  Disconnect the power before cleaning.
•  Make sure there is no power to the unit before 
beginning to maintain or repair the unit in order to 
prevent accidents caused by electrical shock.
Cleaning the air filter
If the air fi lter is blocked with a lot of dust, the air fl ow volume will 
be reduced.  Clean the fi lter once every two weeks.
Open and clean the air fi lter:
1.  Directly grasp the hook on the bottom of the fi lter to remove 
the air-return grids.
2.  Take out the air fi lter from the fi lter cover.
3.  Wash the air fi lter by immersing it gently into warm (about 40°C or 
104°F) water with a neutral detergent or vacuum the fi lter clean.
4. Rinse the fi lter and dry it thoroughly in a shaded place.
5.  Install the air fi lter back to its original place.
!
WARNING
Condensation Handling
Your ZoneAire
®
 Portable Air Conditioner is designed to evapo-
rate the condensation removed from the interior space through 
the exhaust hose.  Under certain conditions it is possible that 
the unit will not evaporate 100% of the removed moisture.
The unit is designed with a built-in reservoir and pump to accu-
mulate excess condensate and help dispose of it.
Internal Water Level
1.  Under any mode if the water level is in the “low” area the unit 
will function normally.
2.  If the water level is in the “normal” area the unit will continue 
to function normally with the internal recirculation pump run-
ning to evaporate the water.  You may hear the pump run at 
times.
3.  If the water level is in the “high” area the unit will function nor-
mally and the water pump will work for 10 minutes.  After that, 
if the water level returns to the “low” or “normal” level the unit 
will function normally.  If after running 10 minutes, the water 
level is still in the “high” area the machine will turn off and the 
WATER FULL lamp on the control panel will illuminate.  The 
LCD window indicates failure code E5.
Draining Water
The water can be drained from the unit either by removing the 
base stopper and letting the water drain by gravity.  Or the con-
densate pump hose may be used to direct the condensate to a 
drain location like a sink.
1.   When the WATER FULL lamp is on unplug the unit and move 
the unit to a suitable location for draining the condensation.
2.  If using the gravity drain method ensure that the base stop-
per is located above a suitable area for draining the conden-
sate and remove the stopper.  Re-install the stopper once all 
water has drained.  
 
If using the condensate removal pump ensure that the conden-
sate pump hose is located in a proper area for drainage.  Re-
store power to the unit and press both the TIMER and SWING 
buttons simultaneously and the pump will begin to run.  
3.  Return the unit to the original location and restore power and 
duct connections.
4.  The WATER FULL indicator should be off and the unit will 
return to normal operating mode.
water tank
water