Whirlpool 819041994 Manual Do Utilizador

Página de 32
10
Display Symbols
Exhaust Air
The Exhaust Air feature allows the air conditioner to either 
recirculate inside air (CLOSED) or exhaust air to the outside 
(OPEN).
CLOSED—used when maximum cooling is desired. It may 
also be used for air recirculation without cooling when the air 
conditioner is set to Fan mode.
OPEN—removes stale air from the room and exhausts it to 
the outside.
NOTE: The OPEN or CLOSED position can be used with any 
mode selection. 
Mode
1. Press MODE until you see the indicator light come on for the 
setting you desire.
2. Choose Cool, Heat (on some models), Fan Only or Power 
Saver.  
Cool—Cools room. Press FAN SPEED to choose fan 
speed. Then adjust the temperature by pressing the plus 
or minus buttons.
Heat (on some models)—The unit will circulate and heat 
the air.
When heater is powered off, Low fan will automatically 
stay on and run for 30 seconds. 
Fan Only—Operates the fan at Low, High or Turbo speed, 
without cooling. Display will show the current room 
temperature.
Power Saver—The fan will switch off whenever the 
compressor turns off in response to the set temperature. 
When the compressor cycles back on, the fan will return 
to the set fan speed.
Fan Speed 
1. Press FAN SPEED until you see the indicator light come on 
for the setting you desire.
2. Choose Auto, Low, High or Turbo. 
When Auto is selected, the fan speed will change 
automatically as the temperature in the room changes.
7º or more above the set temperature will use Turbo.
4º - 7º above the set temperature will use High.
4º or below the set temperature will use Low.
Temperature 
Press the TEMP plus pad. Display shows the Temperature control 
setting. Each time you press or hold the plus button, the 
temperature will increase 1º until it reaches 88°F (31ºC).
NOTE: After 3 seconds, display will show the set room 
temperature.
Press the TEMP minus pad. Display shows the Temperature 
control setting. Each time you press or hold the plus button, the 
temperature will decrease 1º until it reaches 66°F (19ºC).
NOTE: After 3 seconds, display will show the set room 
temperature.
To change the temperature display from ºF to ºC
Press both pads at once to switch the display from ºF to ºC.
Timer Delay
To set Timer for a 0.5- to 24-hour delay before air 
conditioner turns Off (air conditioner must be On):
1. Press TIMER. Timer indicator light will remain on. Display will 
show remaining hours before air conditioner will turn off.
2. Press the plus or minus pad to change the delay time from 
0.5 to 24 hours.
3. Press TIMER again or wait 10 seconds. Timer indicator light 
will remain on. Display will show remaining hours before air 
conditioner will turn off.
4. To turn Timer off, press TIMER again, or press POWER to turn 
off the air conditioner.
A. Cool mode indicator light
B. Fan only mode indicator light
C. Heat indicator light (on some 
models)
D. Power Saver indicator light
E. Timer indicator light
F. Auto fan mode indicator light
G. Low fan mode indicator light
H. High fan mode indicator light
I. Turbo fan mode indicator light
F
G
A
B
C
D
E
H
I