Remove the grommet “E” shown in the photo 4, make a hole in it and pass
the room thermostat wire through.
Remove the link located in the terminal block and connect the wire.
Replace the grommet and the terminal block to their original positions, close 
the cover on the grommet compartment and fasten the wire-clamp “D” in 
place.
If a remote time clock is to be fitted, disconnect the integral time clock plug 
from the P.C.B.
Using a volt-free switching time clock, connect the switching wires from the 
time clock following points 1-6 above.
If using a time clock and room thermostat, these must be connected in 
series as per points 1-8 above.
Note:
Only a two-wire type room thermostat can be used.
For details on fitting the D.H.W. probe (Genus 27 RFFI only),
please consult the separate instruction sheet supplied with the 
probe.
An anti-frost device is built-in to the appliance’s electronic 
regulation system.
2.10 Room Thermostat 
Connection
In order to perform this procedure, remove the boiler casing as indicated in
section 3.2. Then proceed as follows:
Remove the two screws “A” in order to remove the cover, release the two
clips “B” and lift and rotate down the control panel box.
Open the cover “C” on the left hand side of the compartment.
Insert the wire for the connection of the room thermostat into the cable
clamp “D”, as indicated in photo 3.