Ariston E-COMBI 24 30 38 Manual Do Utilizador

Página de 56
boiler protection devices
32
Boiler protection devices
The boiler is protected from malfunctioning by means of internal 
checks performed by the electronic microprocessor P.C.B., which 
stops the boiler from operating if necessary.
In the event of the boiler being shut off  in this manner, the led code 
shows the type of shut-off  and the reason behind it.
There are two types of shut-off :
Safety shut-off  
This type of error is “volatile”, which means that the boiler starts up 
again automatically as soon as the problem which caused the shut-off  
is removed; the yellow led 9 blinks and green CH temperature leds 1 
indicate the error code- see table below.
As soon as the cause of the shut-off  disappears, the boiler starts up 
again and continues to operate normally.
Note : In the event of insufficient water pressure inside the heating 
circuit, the boiler will perform a safety shut-off  (yellow led 9 blinks - leds 
50-60 blink – see table). To re-pressurise the boiler, it will be necessary 
to connect the silver fl exible hose supplied to the two isolating points 
underneath the boiler, once the hose is connected, open up both of 
the black quarter turn handles until the pressure reads 1.5 bar on the 
pressure gauge. If the pressure drops very frequently, there may be a 
water leak at some point in the system.
Shutdown
This type of error is “non-volatile”, which means that it is not removed 
automatically. 
The red led 8 light and green leds 1 indicate the error code- see table 
below.
To restore normal operation press the 
 button on the control 
panel.
Table summarising error codes
Green Leds 
Temperature indicator
Reset
  
Note
Description 
❍ = flashing light
 
● = lit
40
50
60
70
80
90
yellow
red
X
Overheat
X
Insuffi
  cient circulation
Insuffi
  cient water pressure (request fi lling)
C.H. Flow temp. probe circuit open / short circuit
C.H. Return temp. probe circuit open / short circuit
External sensor circuit open / short circuit
Floor thermostat contact open
X
Heating delivery probe problem
Insuffi
  cient circulation
EEPROM error
Communication error
Too many (> 5) resets in 15 minutes
X
Main P.C.B. error
Room sensor circuit open / short circuit
X
No fl ame detected
 Flame detected with gas valve closed
X
Flame lift
1st Ignition Failed
2nd Ignition Failed
Flame cut-off 
X
 Thermofuse  open
X
Fan speed error
Important
If this shutdown occurs frequently, contact an authorised 
Technical Service Centre for assistance. For safety reasons, the 
boiler will permit a maximum of 5 resets in 15 minutes (5 presses 
of the 
 button).
Anti-frost Device. 
When the electrical supply is turned on the anti-frost function acts 
on the central heating fl ow temperature probe, independently from 
other safety devices.
If the primary circuit temperature is between 3°C and 8°C the 
pump will run (with the diverter valve switching between central 
heating and hot water every 1 minute) until the temperature 
reaches > 9°C.
If the fl ow temperature remains between 3°C and 8°C the pump will 
continue to run for a maximum of 20 minutes unless a temperature 
above > 9°C is detected in the central heating fl ow, after this the 
burner will fi re (heating position) until a temperature of > 30°C is 
detected.
If the central heating fl ow temperature is < 3°C, the burner will fi re 
(heating position) at minimum power until the temperature reaches 
> 30°C, the burner will go out.
If lockout is caused by overheat the burner will not fi re but the pump 
will continue to run (heating position).
The anti-frost device activates only when the boiler operating 
correctly :
-  the system pressure is correct;
-  the boiler is electrically powered;
-  there is a supply of gas.