Ariston E-COMBI 24 30 38 Manual Do Utilizador
maintenance guide
42
1
2
3
4
5
Legend
1. Left hand hydraulic block
2. By-pass assembly
3. Safety valve
4. Central heating fl ow
5. Domestic hot water outlet
Tools
Time
10 min
1
Drain primary and domestic hot water circuits.
Remove the two screws and remove the heat exchanger
Remove the two screws and remove the heat exchanger
Left hand Hydraulic block assembly
Secondary Heat Exchanger (E-COMBI)