Ariston E-COMBI 24 30 38 Manual Do Utilizador
maintenance guide
48
Tools
Time
15 min
1
Remove the silencer
Isolate the gas supply. Remove the four
screws and disconnect the gas pipe from
the gas valve
screws and disconnect the gas pipe from
the gas valve
Pull the assembly towards you
2
Note: Any work carried out on the
combustion assembly requires
a combustion analysis check on
completion of work
combustion assembly requires
a combustion analysis check on
completion of work
Remove the three screws to free the burner
door
door
Pull the burner toward you
1
1
3
3
2
2
1.Stainless Steel Burner
Power
Length
Venturi
24 KW
104.6 mm
Ø 42 mm
30 KW
135.8 mm
/
2. Ignition electrode
3.Detection electrode
38 KW
167 mm
/
Burner