Ariston E-COMBI 24 30 38 Manual Do Utilizador

Página de 56
maintenance guide
48
Tools
 
 
 
 Time
 
 
15  min
1
Remove the silencer
Isolate the gas supply. Remove the four 
screws and disconnect the gas pipe from 
the gas valve
Pull the assembly towards you 
2
Note: Any work carried out on the 
combustion assembly requires 
a combustion analysis check on 
completion of work
Remove the three screws to free  the burner 
door
Pull the burner toward you 
 
1
3
3
 
2
2
 
1.Stainless Steel Burner
Power
Length
Venturi
24 KW
104.6 mm
Ø 42 mm
30 KW
135.8 mm
/
2. Ignition electrode
3.Detection electrode
38 KW
167 mm
/
Burner