Making the Electrical Connections
Hinge down the electrical box to gain access to the
electrical connections. Push in the tabs (Fig. 30)
on either side of the boiler and pivot the box for-
ward. 
Remove the PCB cover (see Section 18.4).
Connect the live neutral and  earth wires to the main
cable.
If using a room thermostat or other external control,
they can be connected in place of the link on the ter-
minal block (Diagram A- Fig. 32).
Note: Use only controls designed for voltage free
switching or 24V supply. Do not connect to a 230V
supply, and do not run 230v cables alongside the
low voltage cables.
All necessary settings for room thermostat opera-
tions are described in Section 17 ADJUSTMENTS
AND SETTINGS.