18.2.2 Removing the burner
18.2.3  Removing the detection electrode
1. Carry out step 18.1.1  and 18.2.1
(without removing the 4 nuts D);
2. Remove the 3 screws from the
air/gas manifold (Fig. 58);
3. Slide the burner out from the front,
taking care not to damage the
insulation (Fig. 59a 24 kW & 59b
30 kW);
4. Reassemble in reverse order and 
checking all seals are undamaged
and the burner is positioned
correctly (Fig. 60).
If necessary, replace the insulation
too.
1. Carry out step 18.1.1;
2. Disconnect the detection electrode 
cable (Fig. 61);
3.Remove the 2 screws from the
electrode manifold (Fig. 62); 
4. Pull the electrode from the
combustion chamber (Fig. 63);
5. Reassemble in reverse order.
18.2.4  Removing the ignition electrode
1. Carry out step 18.1.1;
2. Remove the earth cable from the
electrode (Fig. 64);
3. Remove the electrode cable from
the ignitor (Fig. 65);
4. Unscrew the 2 screws on the
electrode (Fig. 66);
G
Fig. 59b
D
Fig. 59a
Do not remove the burner unless absoluly necessary.