Ariston System A 30 RFF Manual Do Utilizador
47
F
Fig. 58
Fig. 60
Fig. 61
Fig. 62
Fig. 63
Fig. 64
Fig. 65
Fig. 66
H
I
18.2.2 Removing the burner
18.2.3 Removing the detection electrode
1. Carry out step 18.1.1 and 18.2.1
(without removing the 4 nuts D);
2. Remove the 3 screws F from the
air/gas manifold (Fig. 58);
3. Slide the burner out from the front,
taking care not to damage the
insulation (Fig. 59a 24 kW & 59b
30 kW);
insulation (Fig. 59a 24 kW & 59b
30 kW);
4. Reassemble in reverse order and
checking all seals are undamaged
and the burner is positioned
correctly (Fig. 60).
If necessary, replace the insulation
too.
and the burner is positioned
correctly (Fig. 60).
If necessary, replace the insulation
too.
1. Carry out step 18.1.1;
2. Disconnect the detection electrode
2. Disconnect the detection electrode
cable (Fig. 61);
3.Remove the 2 screws G from the
electrode manifold (Fig. 62);
4. Pull the electrode from the
combustion chamber (Fig. 63);
5. Reassemble in reverse order.
18.2.4 Removing the ignition electrode
1. Carry out step 18.1.1;
2. Remove the earth cable from the
2. Remove the earth cable from the
electrode (Fig. 64);
3. Remove the electrode cable H from
the ignitor (Fig. 65);
4. Unscrew the 2 screws I on the
electrode (Fig. 66);
G
Fig. 59b
D
Fig. 59a
Do not remove the burner unless absoluly necessary.