Ariston G.C.N.:47-116-66 (30 kW) Manual Do Utilizador

Página de 72
15
installation
 Gas  connection 
Make sure, using the labels on the packaging and the data plate 
on the appliance itself, that the boiler is in the correct country 
and that the gas category for which the boiler was designed 
corresponds to one of the categories available in the country 
where it will be used.
The gas supply piping must be created and measured out in 
compliance with specifi c legal requirements and in accordance 
with the maximum power of the boiler.
Check that the supplied gas corresponds to the type of gas for 
which the boiler was designed (see the data plate located on the 
appliance itself ). 
It is also important to check that the pressure of the gas (methane 
or LPG) you will be using to feed the boiler is suitable, because if it 
is insuffi
  cient the power may be reduced, causing inconvenience 
for the user. 
Instructions for opening the casing and performing an 
internal inspection
Before performing any work on the boiler, fi rst disconnect it from 
the electrical power supply using the external bipolar switch 
removing the fuse and shutting off  the gas valve.
To access the inside of the boiler, the following is necessary:
1.  Remove the casing by unhooking it from the control panel (a)
2.  Loosen the two screws on the front casing (b), pull it forwards 
and unhook it from the upper pins (c)
3.  Lower the control panel (d)
4.  Unhook the two clips on the combustion chamber panel and 
lift off  (e).
  (c)
Water connection 
The illustration below shows the connections for the water and 
gas attachments of the boiler.  See valves confi guration on page 
14.
Check that the maximum water mains pressure does not exceed 6 
bar; if it does, a pressure reducing valve must be installed. 
For the measuring of the pipes and of the heating bodies in the 
heating system, the residual head value should be calculated as a 
function of the requested fl ow rate, in accordance with the values 
shown in the circulation pump graph.
 A. Central heating Flow 
 
B.  Domestic Hot Water Outlet 
C. Gas Inlet 
 
 
D. Domestic Cold Water Inlet 
E.  Central Heating Return
F.  Safety Valve Discharge
H. Drain Valve 
I. Drain condensate