installation
Installing the Boiler
Please check that you are familiar with the installation requirement 
before commencing work (pages 11 - 15).
The installation accessories described in the following list are 
included in the boiler packaging:
- Hanging 
bracket
-  A paper template (showing the dimensions of the boiler with 
  5 mm side clearances)
-  Connection valves (compression)
-  Screws and washers
- Filling 
loop
-  Installation, Servicing and User manual
Method of positioning the boiler on the wall
The paper template can be used to ensure the correct positioning 
of kitchen cabinets etc.
The paper template has to be fi xed to the wall and used to locate 
the position of the hanging bracket and the centre for the fl ue 
hole.
Drill and plug the wall and secure the hanging bracket using the 
screws provided ensure the hanging bracket is level.  Remove the 
boiler from its packaging and remove the front casing panel.
Place the boiler on the hanging bracket.
N
OTE
: T
HE
 
APPLIANCE
 
MUST
 
NOT
 
BE
 
FITTED
 
ON
 
A
 
COMBUSTIBLE
 
WALL
 
SURFACE
.
Connecting the boiler to the system
-  Remove the boiler casing as described on page 15
-  Remove the caps and connect the valves to the boiler using 
  the washers provided
-  5 x fi bre washers for the CH fl ow and return, cold water inlet, gas 
  and hot water outlet connections
Safety Valve Discharge
The pressure relief valve pipe is made of copper.  It should 
terminate below the boiler safely outside the premises.  Care 
should be taken that it does not terminate over an entrance or 
window or where a discharge of heated water could endanger 
occupants or passers by.
Warning !
Do not apply heat to the copper safety valve outlet pipe 
whilst it is connected to the 3 bar safety relief valve.
Fill the central heating and DHW system and bleed air from the 
system as described in the Commissioning instructions (page 31).
The system should be carefully checked for leaks, as frequent 
refi lling could cause premature system corrosion or unnecessary 
scaling of the heat exchanger.  The pipe from the trap should be 
connected to a drain as described in the relevant regulations.
Pay special attention not to bend the condensate silicone drain 
pipe is such a way as to interrupt the fl ow.  Please only use drain 
pipe material compatible with condensate products (refer to BS 
6798:2000).
The condensate fl ow can reach 2 litres/hour because of the acidity 
of the condensate products (Ph close to 2), take care before 
operation.
See page 13 for condensate discharge options.
Note: Connections viewed from behind boiler
A
A
- remove the 2 screws A from the transport bar
- dispose of the transport bar and reassemble 
the fi xing screws.
Note: Connections viewed from behind boiler
CLAS HE EVO
CLAS HE EVO SYSTEM
Note. 
Connections viewed from 
behind boiler.