INSTALLATION INFORmATION
STOVE LOCATION
Plan for the installation of your stove. This includes deter-
mining where the unit is to be installed, the vent configura-
tion to be used, framing and finishing details, and whether 
any optional accessories (i.e. blower, wall switch, or remote 
control)  are  desired.  Consult  your  local  building  code 
agency to ensure compliance with local codes, including 
permits and inspections.
The following factors should be taken into consideration:
  This  stove  should  have  sufficient  access  for  its  safe 
operation and maintenance.
  Locate a position where the flue system of the stove can 
be properly installed without damaging the integrity of 
the building. e.g. cutting wall or ceiling joist (example: 
load-bearing framing members).
  When the appliance is installed directly on carpeting, 
tile or other combustible material other than wood floor-
ing, you must set appliance on a metal or wood panel 
extending the full width and depth of the appliance.
  Check stove and flue system clearance requirements.
  Locate the stove where it can be accessed by a gas 
supply line.
  Locate  the  stove  in  a  large  and  open  room  that  is 
centrally located in the house. This will optimize heat 
circulation and comfort.
  The flow of combustion and ventilation air must not be 
obstructed.
  Minimum clearances to combustibles, side-wall, ceiling, 
woodwork, and windows must be maintained. Page 
9, Figure 4
  This stove may be installed along a wall, across a corner, 
or use an exterior chase. Refer to Figure 3 for suggested 
locations.
  Location should be out of high traffic areas and away 
from  furniture  and  draperies  due  to  heat  from  appli-
ance.
  Never obstruct the front opening of the stove.
  Do  not  install  in  the  vicinity  where  gasoline  or  other 
flammable liquids may be stored.
  Vent  pipe  routing.  See  Venting  section  found  in  this 
manual for allowable venting configurations.
  These units can be installed in a bedroom. See National 
Fuel Gas Code ANSI Z233.1/NFPA 54 (current edition), 
the  Uniform  Mechanical  Code  (current  edition),  and 
Local Building Codes for specific installation require-
ments.
NOTE: If this unit is installed in a mobile home it must be 
bolted securely to the floor with leg bolts.
NOTE: Stoves work without any electrical supply. 
ON
OFF
ST1127
stove locations
Figure 3 - 
Possible Stove Locations
ST1127