Vivitek D5280U Manual Do Utilizador

Página de 66
Prefacio 
 55  
A
PÉNDICE 
RS-232C Protocol 
RS232 Setting
 
Baud rate:
 
9600
 
Parity check:
 
None
 
Data bit:
 
8
 
Stop bit:
 
1
 
Flow Control
 
None
 
Control Command Structure
 
 
 
Header code 
Command code 
Data code 
End code 
HEX 
 
 Command Data 0Dh 
ASCII ‘V’  Command  Data  CR 
Operation Command 
Note: 
XX=00-98, projector's ID, XX=99 is for all projectors 
Return Result P=Pass / F=Fail 
n: 0:Disable/1: Enable/Vaule(0~9999) 
Command Group 00 
ASCII 
HEX 
Function 
Description 
Return Result
VXXS0001  56h Xh Xh 53h 30h 30h 30h 31h 0Dh 
Power On 
 
 P/F 
VXXS0002  56h Xh Xh 53h 30h 30h 30h 32h 0Dh 
Power Off 
 
 P/F 
VXXS0003  56h Xh Xh 53h 30h 30h 30h 33h 0Dh 
Resync 
 
 P/F 
VXXG0004  56h Xh Xh 47h 30h 30h 30h 34h 0Dh 
Get Lamp Hours 
 
 Pn/F 
VXXS0005n  56h Xh Xh 53h 30h 30h 30h 35h nh 0Dh Set Air filter timer  n=0~999999  P/F 
VXXG0005  56h Xh Xh 47h 30h 30h 30h 35h 0Dh 
Get Air filter timer n=0~999999  Pn/F 
VXXS0006  56h Xh Xh 53h 30h 30h 30h 36h 0Dh 
System Reset 
 
 P/F 
VXXG0007  56h Xh Xh 47h 30h 30h 30h 37h 0Dh 
Get System Status
0:Reset 
1:Standby 
2:Operation 
3:Cooling 
Pn/F 
VXXG0008  56h Xh Xh 47h 30h 30h 30h 38h 0Dh    Get F/W Version     Pn/F 
VXXG0009  56h Xh Xh 47h 30h 30h 30h 39h 0Dh    Get Alter EMail 
 
 Pn/F 
VXXS0009n  56h Xh Xh 53h 30h 30h 30h 39h nh 0Dh Set Alter Email 
P/F