REAR PANEL
Audio Signal Inputs
The electronically balanced inputs facilitate the connection of external signal sources 
(e.g.  mixing  consoles).  When  screwed  to  the  power  amp,  the  screwlock  connectors 
provided with the unit prevent accidental disconnection.
Choosing balanced cables (2 conductors for audio signals + separate shielding mesh) 
for LF-signal connection is generally recommended, even when the connected signal 
source does not provide balanced output signals. This is possible by jointly connecting 
“–” conductor and shield on the source side (also refer to “LF-Connection Cords).
Level Controls
The  Level  Controls  allow  setting  the  according  power  amp  channel’s  overall 
amplification. To prevent distortion in mixing consoles connected to the amp, setting 
these controls to a value between -6dB and 0dB is generally recommended. A scale 
provides direct indication of the varying additional control attenuation applied to the fixed 
internal amplification.
Mode Switch
The Mode Switch allows selecting the power amp’s mode of operation. With the four-
channel model it is possible to independently select channels A and B or C and D.
The single-channel model comes without mode switch.
DUAL: 
The power amp channels work independently from each other, each re-
 
producing the audio signals fed to the corresponding input.
PARALLEL:  Both channels reproduce the audio signal fed to input A (or C). However, 
 
using the level controls allows individually setting the channel volumes.
BDGD: 
Audio signals need to be fed to channel A (or C) when in Bridged Mode. 
Power  amps  A  and  B  (or  C  and  D)  now  work  in  push-pull  operation 
delivering  doubled  output  voltage.  Please  keep  in  mind  to  correctly 
connect the loudspeaker systems for Bridged Mode operation. (also refer 
to “Loudspeaker Outputs”)
High Pass Filter (HPF)
The Hi-Pass filter allows effective attenuation of low bass audio signals. You can choose 
from three cut-off frequency settings:
Power Amps with low impedance outputs
Power Amps with output transformer
300Hz, 12dB/Oct., BW
300Hz, 12dB/Oct., BW
50Hz, 12dB/Oct., BW
70Hz, 12dB/Oct., BW
OFF (no Hi-Pass filter)
50Hz, 18dB/Oct., BW
As a basic principle, all models with output transformer have a 50Hz Hi-Pass filter in the 
audio signal path to protect the transformer from being driven into saturation by high 
level low-frequency signals.