INSPECTING HEATER 
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN
Figure 20 
shows a correct pilot flame pattern.
Figure 21 
shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause 
the thermocouple to cool. When the thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 21 
 
•   turn heater off (see “To Turn Off Gas to Appliance,” page 21)
 
•   see “Troubleshooting,” pages 24 through 26
BURNER FLAME PATTERN
Figure 22 
shows a correct burner flame pattern. Figure 23 shows an incorrect burner flame pattern. The incorrect burner 
flame pattern shows yellow tipping of the flame. It also shows the flame higher than one inch above the log.
Note: When using the heater the first time, the flame will be opaque orange/yellow for approximately one 
hour until the log cures. 
Thermocouple
for Natural 
Thermocouple
for LP
Figure 21 - Correct Pilot Flame Pattern
Thermocouple
for Natural 
Figure 22 - Incorrect Pilot Flame 
Pattern Pilot Burner
Thermocouple
for LP
If  yellow  tipping  occurs,  your  heater 
could  produce  increased  levels  of 
carbon  monoxide.  If  burner  flame 
pattern  shows  yellow  tipping,  follow 
instructions, bottom of this page.
W
ARNING
If pilot flame pattern is incorrect, as shown 
in Figure 23,
 
•   turn heater off (see “To Turn Off Gas 
to Appliance,”
 page 21)
 
•   see  “Troubleshooting,”  pages  24 
through 26.
Do  not  mistake  orange  flames  with 
yellow  tipping.  Dirt  or  other  fine 
particles  enter  the  heater  and  burn 
causing  brief  patches  of  orange 
flame.
NOTICE
Figure 24 - Incorrect Burner 
Flame Pattern
Figure 22 - Correct Burner 
Flame Pattern
Top of Flame Even 
with Top of Log 
Yellow Tippping