Graco 1050C Manual Do Utilizador

Página de 24
Installation 
8
312877P
Mounting
1. For wall mounting, order Graco Kit 24C637.
2. Be sure the mounting surface can support 
the weight of the pump, hoses, and acces-
sories, as well as the stress caused during 
operation. 
3. For all mountings, be sure the pump is 
bolted directly to the mounting surface.
4. For ease of operation and service, mount 
the pump so air valve, air inlet, fluid inlet 
and fluid outlet ports are easily accessible.
5. Rubber Foot Mounting Kit 236452 is avail-
able to reduce noise and vibration during 
operation.
Grounding
Pump: See F
IG
. 1. Loosen the grounding 
screw (GS). Insert one end of a 12 ga. 
minimum ground wire (R) behind the 
grounding screw and tighten the screw 
securely. Connect the clamp end of the ground 
wire to a true earth ground. A ground wire and 
clamp, Part 238909, is available from Graco.
Air and fluid hoses: Use only grounded 
hoses with a maximum of 500 ft (150 m) com-
bined hose length to ensure grounding conti-
nuity. 
Air compressor: Follow manufacturer’s
recommendations.
Fluid supply container: Follow local code.
Solvent pails used when flushing: Follow 
local code. Use only conductive metal pails, 
placed on a grounded surface. Do not place 
the pail on a nonconductive surface, such as 
paper or cardboard, which interrupts ground-
ing continuity.
The pump exhaust air may contain contam-
inants. Ventilate to a remote area. See Air 
Exhaust Ventilation 
on page 10.
Never move or lift a pump under pressure. 
If dropped, the fluid section may rupture. 
Always follow the Pressure Relief Proce-
dure
 on page 15 
before moving or lifting 
the pump.
The equipment must be grounded to reduce 
the risk of static sparking.  Static sparking can 
cause fumes to ignite or explode.  Grounding 
provides an escape wire for the electric 
current.
Polypropylene and PVDF: Only aluminum, 
conductive polypropylene, hastelloy, and 
stainless steel pumps have a ground screw. 
Standard polypropylene and PVDF pumps 
are not conductive. Never use a non-conduc-
tive polypropylene or PVDF pump with 
non-conductive flammable fluids. Follow your 
local fire codes. When pumping conductive 
flammable fluids, always ground the entire 
fluid system as described.
F
IG
. 1. Grounding screw and wire
ti12214a
GS
R