OPERATING PRESSURES
 
Minimum/Maximum ..................................................................................................................................25 psi-125 psi
 
OPERATING TEMPERATURES
 
Minimum/Maximum ..................................................................................................................................40º - 110º F
METER
 
Accuracy ...................................................................................................................................................±5%
 
Flow Rate Range......................................................................................................................................0.25 - 34 GPM
 
Gallon Range ...........................................................................................................................................20 - 50,000 
DIMENSIONS
 
Drain Line .................................................................................................................................................3/4” or 1” NPT
 
Brine Line .................................................................................................................................................3/8” Poly Tube
 
Electrical Current Draw and Voltage ........................................................................................................0.5A 110v
Compatible with the following regenerants or chemicals:  Sodium chloride, potassium permanganate, sodium bisulfite, sodium hydroxide, 
hydroxide, hydrochloric acid, chlorine and chloramines.
General speCifiCaTiOns
prOGraMMinG OpTiOns
AUTO
DELAY 
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at the next 
Regen Set Time.
AUTO
DELAY 
1 to 28
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity falls below the 
reserve capacity or the specified number of days between regenerations is reached.
DELAY  
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0.
DELAY  
oFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of days 
between regenerations is reached.
DELAY 
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the 
specified number of days between regenerations is reached.
AUTO
IMMEDIATE
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because of regeneration will always 
occur when gallons capacity reaches 0.
DELAY + IMMEDIATE
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration will not be allowed to be set because regeneration will always 
occur on 0.
AUTO
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
capacity at the next Regen Set Time or regeneration occurs immediately after 
10 minutes of no water usage when gallon capacity reaches 0.
AUTO*
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity 
falls below the reserve capacity or the specified number of days between regenerations
is reached or regeneration occurs immediately after 10
minutes of no water usage when gallon capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when specified number of days be-
tween regenerations is reached or regeneration occurs immediately after 10 minutes 
of no water usage when gallon capacity reaches 0.
1 to 28
1 to 28
1 to 28
1 to 28
*14
20 to
250,000
20 to
250,000
20 to
250,000
20 to
250,000
Reserve
Gallons
Regeneration
Type
Days
Override
Results 
(Reserve capacity estimate based on history of water usage)
*Factory settings in bold
To "lockout" access to modification settings, diagnostic and valve history displays except hardness, day override and time, 
press   
X    
next,   
 X
 and clock in sequence to "unlock" press   
X
   next,   
z
 and clock in sequence.
DELAY + IMMEDIATE
DELAY + IMMEDIATE