Novatel OM-20000149 Manual Do Utilizador

Página de 66
Installation and Setup
Chapter 2
AG-STAR User Manual Rev 2
13
4. Connect the NovAtel or custom cable to the power supply and turn on the power supply. The power LED 
 on the receiver glows red when the AG-STAR is properly powered.
 Figure 3: Simplified AG-STAR Setup
2.1.2
Power Supply Requirements
The AG-STAR requires +8 to +36 VDC for the input power to the receiver. See Section A.2, AG-STAR 
Specifications
 on page 43
 
for additional power supply specifications.
The AG-STAR cable provides power in (labelled BATT+) and power ground (labelled BATT-) bare wires for 
connections from the AG-STAR to a vehicular power system (or equivalent). For cable details see 
Section A.2.3, AG-STAR Connector and Cable Requirements on page 48.
Fuse/holder recommendations can be found in Table 9, Recommended Fuse and Fuse Holders 
on page 48
.
Minimum conductor size for all wiring is 0.5 mm / 20 AWG.
COM
COM
Emulated
Radar
MKI
PPS
User supplied 
5A fast blow fuse
CAN
The AG-STAR power source must be protected by a 5A fast blow fuse (user supplied) or 
damage to wiring may result (not covered by warranty).