HP (Hewlett-Packard) 1.16 Manual Do Utilizador

Página de 13
 
Known issues  11 
User interface 
 
Virtual Connect Manager allows users to change the number of VC-FC Module uplink ports 
connected to an external Fabric Switch without a warning while a server might be accessing remote 
storage devices. 
 
Virtual Connect Manager shows either a server blade or an interconnect module as degraded (but 
not both) for an I/O Ekey mismatch. 
 
If non-Administrator credentials are entered for the Onboard Administrator during Virtual Connect 
Domain Import, the import fails without explanation. The VC-Enet module must be power cycled to 
recover and allow for entry of new OA credentials. 
 
Network uplinks that are linked after the Network Setup Wizard has been started may not show 
proper link status in the wizard. When the wizard is completed, all uplink link statuses are displayed 
correctly. 
 
The main window of the GUI might show more updated information than the left window. Refresh the 
page to synchronize. 
 
A server profile can be assigned to a device bay with a server that has fewer physical NIC ports 
than defined in the server profile. In most cases, a warning is provided, but in some cases it is not. 
 
If a server is rebooted several times while its server profile is being edited, an error displaying an 
XSL transformation failure may be displayed. Do not edit a server profile while repeatedly rebooting 
a server. 
 
In the Bay Summary screen for a VC-FC module in Virtual Connect Manager, some servers might be 
displayed with the incorrect model number. The model number is displayed correctly in other screens 
and in the Onboard Administrator. 
 
When using Internet Explorer 6 or Internet Explorer 7, some web pages do not display correctly on 
machines configured for Chinese language options. Change the language encoding in Internet 
Explorer to "Western European (ISO)" or use Mozilla Firefox. 
 
In the Server Connections tab of the Ethernet Networks screen, the port status shows OK even if the 
server port is not linked. 
 
Firmware update 
 
The VC-Enet module firmware must be updated before the VC-FC module firmware. Otherwise, the 
VC-FC firmware might not appear to be successfully updated. 
 
If the firmware update procedure indicates a failure to activate a module or appears to be stuck, it 
might be caused by a timeout and/or a stale web page. To refresh the screen and verify the actual 
update status, click the Firmware update link under Domain Settings in the left navigation pane of 
the VCM user interface. 
 
During the firmware update activation countdown, an Internet Explorer pop-up might be displayed 
stating "Failed to create processor object: The stylesheet does not contain a document element. The 
stylesheet may be empty, or it may not be a well-formed XML document." This pop-up can be 
dismissed without consequences.