Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-449
CONFIG (System Configuration) 
9
CONFIG (System Configuration)
The System Configuration maintenance object (MO) oversees logical insertion 
and removal of circuit packs in the system. When Switch Control detects that a 
circuit pack is present in a port slot, it informs System Configuration and System 
Configuration queries the circuit pack to determine the type and vintage of the 
circuit pack. Similarly, when Switch Control detects that a circuit pack has been 
removed from a port slot, it informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors 
are logged to the Hardware Error Log.
Error Log Entries and Test to Clear Values
Notes:
a. This error indicates that a port circuit pack in the system did not respond 
to a circuit pack type inquiry. Follow the procedures outlined in (b) to 
determine if there is an error.
b. This error indicates that less than 25% of Trunk Group is available.
c. This error indicates that a port circuit pack in the system did not respond 
to a vintage inquiry.
As a result of either of these errors, a port circuit pack may be physically 
inserted in a port slot, but the system may not recognize its existence. The 
Aux Data field specifies the circuit pack’s port-network number as 
indicated in the following table.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
CONFIG
none
none
System Configuration
Table 9-187.
System Configuration Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
This error should not occur. It indicates that an attempt was made by software to raise an alarm 
against CONFIG without first logging a CONFIG error.
0
none
none
N/A
none
1-119 (a)
0-21
none
257(b)
none
MAJOR
1001-111
9 (c)
0-21
none