Lucent Technologies Release 7 Manual Do Utilizador

Página de 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-908
HYB-LINE (Hybrid Line) 
9
Error Log Entries and Test to Clear Values
Notes:
a. The data link between the port and the terminal is not operational. (An 
off-board problem was detected by port circuit). Verify that the Hybrid set 
is connected and that the Electronic Power Feed (EPF) test passes. If data 
transmission problems are experienced, check for defective wiring or a 
defective voice terminal, or move terminal closer to the switch (reduce the 
Table 9-347.
Hybrid Line Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
40987
None
WARNING
OFF
15(j)
Any
Hybrid Line Audits 
Test(#161)
18(b)
0
busyout port 
UUCSSpp
WARNING
OFF
release port UUCSSpp
130(c)
None
WARNING
ON
test port UUCSSpp sh
257(d)
40988
None
MIN/WRN
OFF
513(e)
40965
Hybrid Line Audits 
Test (#61)
WARNING
OFF
test port UUCSSpp sh r 4
769(f)
Remote Dig 
Looparound Test 
(#59)
WARNING
OFF
test port UUCSSpp sh r 3
1025
Hybrid & Conf. 
Circuits Test (#57)
MIN/WRN
ON
test port UUCSSpp l r 3
1281(f)
Local Digital 
Looparound Test 
(#58)
WARNING
ON
test port UUCSSpp l r 3
1537(g)
40968
None
WARNING
OFF
1793
TDM NPE Crosstalk 
Test (#6
MIN/WRN
2
2.
Major or minor alarms may be downgraded to Warning alarms based on the value used in the set
options command.
ON
test port UUCSSpp l r 3
2049(h)
32770
None
2049(i)
40967
None