DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-23
TN1654 DS1 Converter (Release 6r Only) 
5
TN1654 DS1 Converter (Release 6r 
Only)
Set Circuit Pack Switches
The configuration switches on the TN1654 must be set before the circuit pack is 
installed. The TN1654 can be configured for either T1 or E1 operation. All 4 
facilities on the circuit pack are configured as a group. It is not possible to have 
T1 and E1 facilities supported on the same circuit pack at the same time. 
E1 facility line termination impedances of 120 Ohms for twisted-pair and 75 
Ohms for coax wiring are supported. The T1 line impedance is fixed at 100 Ohms 
and the T1 framing is selectable for ESF (Extended Super Frame) or D4 for each 
facility. 
 shows the location of the switches. 
Table 5-9
 shows the switch 
setting positions and functions.
1. Set the configuration switches on the TN1654 as required per site.
2. Set Switch 6 down (disabled).
Table 5-9.
TN1654 DS1 Converter Configuration Switches
Switch
Function
Up
Down
1
Type of Facility
T1
E1
2
Span A Line Impedance (E1 Only) 
Span A Framing (T1 Only)
120 Ohm
ESF
75 Ohm
D4
3
Span B Line Impedance (E1 Only) 
Span B Framing (T1 Only)
120 Ohm
ESF
75 Ohm 
D4
4
Span C Line Impedance (E1 Only) 
Span C Framing (T1 Only)
120 Ohm
ESF
75 Ohm 
D4
5
Span D Line Impedance (E1 Only) 
Span D Framing (T1 Only)
120 Ohm
ESF
75 Ohm 
D4
6
Force Fiber Data-Stream 
Scrambling
Enabled
Disabled