Lucent Technologies Release 6 Manual Do Utilizador

Página de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-118
Add CallVisor ASAI 
5
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
Enter 
to verify that the system is in the “active/standby” mode.
2. Enter save translation and press 
Enter
. This instructs the system to take all 
translation information in memory and write it to the translation card or 
tape.
3. If the system contains a TN750 Announcement circuit pack, enter display 
announcements and press 
Enter
.
If administered recorded announcements are listed, enter list 
configuration software-version
 and press 
Enter
. Check Page 2 of this 
form to see when the announcements were last saved. To save the 
announcements, enter save announcements and press 
Enter
.
Power Down System
If the packet bus is being added:
1. At the PPN, set the main circuit breaker to OFF.
2. At each EPN, set the main circuit breaker to OFF.
Add Circuit Packs
1. Determine port assignment of circuit packs to be added.
2. Install the appropriate circuit pack in assigned cabinet slot (as required). 
For example: 
The TN748C or TN744 Call Classifier circuit pack is required. The TN744 is 
required for those customers who desire switch call classification.
A vacant port is required on a TN556 ISDN—BRI circuit pack.
3. A Packet Bus is required with CallVisor ASAI. If the system is not equipped 
with a Packet Bus, see “
” earlier in this chapter.
Port Number
3
B
02
01
Cabinet
(Port Network)
Carrier
Slot
Circuit