Lucent Technologies Release 6 Manual Do Utilizador

Página de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-123
Add ISDN—BRI 
5
Resolve Alarms
1. Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 6 Maintenance for R6r
Contact INADS to Enable Customer Options and
Verify Alarm Origination
1. Be sure the system is part of the existing INADS database by calling the 
INADS Database Administrator at the Technical Service Center (TSC). 
Verify that INADS can dial into the system and that the system can dial out 
to INADS. 
As part of the system registration process, the INADS Database 
Administrator enables Alarm Origination and enables customer options.
!
CAUTION:
If you do not enable Alarm Origination when the customer has 
purchased a services contract, the system cannot report any alarm 
to the TSC automatically, causing the TSC to be unable to fulfill the 
services contract.
Save Translations
1. If the system is high or critical reliability, enter status system 1 and press 
Enter
 to verify that the system is in the “active/standby” mode.
2. Enter save translation and press 
Enter
. This instructs the system to take all 
translation information in memory and write it to the translation card or 
tape.
3. If the system contains a TN750/B Announcement circuit pack, enter list 
configuration software-version and press 
Enter
. If Page 2 of this form 
shows that recorded announcements were saved, these announcements 
can be restored using restore announcements and press 
Enter
.
4. Update backup tape, if required.