Lucent Technologies Release 6 Manual Do Utilizador

Página de 453
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-134
CAMA/E911 Installation 
5
Hardware Setup
1. Insert the TN429C CO circuit pack in any available port slot.
2. Wire the TN429C to the MDF (the trunk from the CO). Refer to the pinouts 
in 
Administration Setup
1. At the prompt, type add trunk next and press 
Enter
.
TN780
Tone Clock
Not Affected
Used in the 
U.S. (infre-
quently) for 
stratum 3 clock-
ing and used in 
many other 
countries
Tone clock only, 
no TTR/CPTR 
functionality. Typ-
ically found with 
TN748 circuit 
packs in the U.S. 
Use TN7744DV2 
instead of TN748 
with CAMA.
TN2182 
TN2182B
Tone Clock / 
Call Classifier - 
Detector
Compatible
Used globally
Tone clock plus 8 
GPTR/call classi-
fication ports. Use 
TN2182B if 
CAMA feature is 
to be supported.
Table 5-24.
Compatibility Tone Clock, TTR/CPTR, and GPTR Circuit Packs
 — 
Continued
Circuit 
Pack
Description
Compatibility
 with CAMA 
Trunks in 
Same PN
Application
Notes
Continued on next page