Install and Connect Cabinets 
Page 1-29
Fiber Optic Interconnect Cabling 
1
Fiber Optic Interconnect Cabling
Signals between the cabinets are carried by fiber optic cables. Lightwave 
transceivers provide the required fiber optic interface. 
The fiber optic cables from the DEFINITY System route to a Lightguide 
Interconnect Unit (LIU) or fiber optic shelf. Refer to 
Appendix A, ‘‘Connecting 
Fiber Optic Cables’’
. Refer to this information for fiber optic equipment comcode 
numbers, connecting to LIUs or shelves, and routing through lightguide 
equipment.
Use multi-mode fiber transceivers and multi-mode fiber optic cables between 
cabinets unless single-mode fiber is required (distance restrictions). Use metallic 
cables between carriers. 
!
CAUTION:
The DEFINITY ECS may contain a Class 1 LASER device if single-mode 
fiber optic cable is connected to a remote Expansion Port Network (EPN). 
The LASER device operates within the following parameters:
Maximum Power Output: -5 dBm
Wavelength: 1310 nm
Mode Field Diameter: 8.8 microns
CLASS 1 LASER PRODUCT
IEC 825 1993
!
CAUTION:
Use of controls or adjustments or performance of procedures other than 
those specified herein may result in hazardous radiation exposure.