3.1 
 PERFORMING  SCHEDULED 
MAINTENANCE
It is important to perform service as specified in the Maintenance 
Schedule for proper generator operation, and to ensure that the generator 
complies with the applicable emission standards for the duration of its 
useful life. Service and repairs may be performed by any capable person 
or repair shop. Additionally, emissions critical maintenance must be 
performed as scheduled in order for the Emissions Warranty to be valid. 
Emissions critical maintenance consists of servicing the air filter and spark 
plugs in accordance with the Maintenance Schedule.
3.2  MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required when 
operating in adverse conditions noted below.
Check Oil Level 
At Each Use
Change Oil ‡ 
*Every 100 hours or Every Season
Check Valve Clearance 
***Every Season
Service Air Filter 
** Every 200 hours or Every Season
Replace Spark Plug 
Every Season
‡  Change oil after first 30 hours of operation then every season.
*  Change oil and oil filter every month when operating under heavy load or in high 
temperatures.
** Clean more often under dirty or dusty operating conditions.  Replace air filter 
parts if they cannot be adequately cleaned.
*** 
Check valve clearance and adjust if necessary after first 50 hours of 
operation and every 100 hours thereafter.
3.3  PRODUCT SPECIFICATIONS
3.3.1  GENERATOR SPECIFICATIONS
MODEL
15 KW
17.5 KW
Rated Max. Power
15.0 kW
17.5 kW
Surge Power
22.5 kW
26.25 kW
Rated AC Voltage
120/240
120/240
Rated Max AC Load
Current @ 240V
62.5 Amps
72.9 Amps
Current @ 120V
125.0 Amps
145.8 Amps
Rated Frequency
60 Hz @ 3600 RPM
60 Hz @ 3600 RPM
Phase
Single Phase
Single Phase
Rated DC Voltage
12 Volts
12 Volts
Rated Max DC Load
Current @ 12 Volts
10 Amperes
10 Amperes
Weight
373 lbs.
400 lbs.
3.3.2  ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM 30
Displacement
992cc
Spark Plug Type
Champion RC14YC or Equivalent
Spark Plug Gap
0.040 inch or (1.01 mm)
Gasoline Capacity
16 U.S. gallons
Oil Type
Summer – SAE 30, Winter – 
5W-30 Synthetic or 10W-30 
Oil Capacity
w/ Filter Change = 1.7 Qts., w/o 
Filter Change = 1.4 Qts.
Run Time/Fuel Consumption-1/2 
Load
10 Hours / 1.6 gallons per hour
3.3.3  EMISSIONS INFORMATION
The Environmental Protection Agency (and California Air Resource Board 
for generators certified to CA standards) require(s) that this generator 
comply with exhaust and evaporative emission standards. Locate the 
emissions compliance decal on the engine to determine what standards 
the generator meets. This generator is certified to operate on gasoline. The 
emission control system consists of the following:
•  Air Induction System
~  Intake Pipe / Manifold
~  Air Cleaner
•  Fuel System
~ Carburetor
~  Fuel Tank / Cap
~  Fuel Lines
~  Evaporative Vent Lines
~  Carbon Canister (for CA engines only)
•  Ignition System
~  Spark Plug
~  Ignition Module
•  Exhaust System
~  Exhaust Manifold
~ Muffler
~  Catalyst (for CA engines only).
3.4  GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been 
subjected to operator abuse or negligence. To receive full value from the 
warranty, the operator must maintain the generator as instructed in this 
manual.
Some adjustments will need to be made periodically to properly maintain 
the generator.
All adjustments in the Maintenance section of this manual should be made 
at least once each season. Follow the requirements in the "Maintenance 
Schedule" chart.
NOTE:
Once a year, replace the spark plug and replace the air filter. A new 
spark plug and clean air filter assure proper fuel-air mixture and help 
the engine run better and last longer.
Maintenance