Campbell Hausfeld IN614207AV Manual Do Utilizador

Página de 24
Operating Instructions and Parts List
4
www.chpower.com
FP202801, FP202901
Installation (continued)
 
 
 
 
 
Improper  
 use of 
grounding plug can result in 
a possible risk of electrical 
shock!
 
Do not use a  
 grounding adapter 
with this product!
2.  If repair or replacement of cord or 
plug is necessary, do not connect 
grounding wire to either flat blade 
terminal. The wire with insulation 
having an external surface that 
is green (with or without yellow 
stripes) is the grounding wire.
 
Never connect  
 green (or green 
and yellow) wire to a live terminal.
3.  Check with a qualified electrician 
or serviceman if grounding 
instructions are not completely 
understood, or if in doubt as 
to whether product is properly 
grounded. Do not modify plug 
provided; if it will not fit outlet, 
have proper outlet installed by a 
qualified electrician.
 
Overheating, short  
 circuiting and fire 
damage will result from inadequate 
wiring.
LUbrIcatIOn
This is an oilless product and DOeS 
nOt
 require lubrication to operate.
Pre-Operation
beFOre FIrSt Start-UP
break-In PrOceDUre
(Complete this procedure before 
using compressor for the first time. 
Once completed, it is not necessary to 
repeat.)
1.  Turn regulator knob fully clockwise 
(to the right) to open air flow.
2.  Do not attach a hose or any other 
fitting to the compressor.
3.  Turn On / OFF switch to OFF 
position.
4.  Plug in power cord.
5.  Turn On / OFF switch to On 
position and run compressor for 30 
minutes.
6.  Turn On / OFF switch to OFF 
position.
7.  Unplug power cord.
The compressor is now ready for use.
beFOre each Start-UP
OPeratInG PrOceDUre
1.  Turn regulator knob fully 
counterclockwise (to the left) to 
close air flow. 
2.  Connect air hose to outlet of 
regulator.
3.  Turn On / OFF switch to OFF 
position.
4.  Plug in power cord.
5.  Turn On / OFF switch to On 
position and let compressor run 
until it reaches automatic shutoff 
pressure.
6.  Attach tire chuck or tool to end of 
hose.
7.  Turn regulator knob clockwise (to 
the right) to desired pressure of 
tool being used.
Operation
Start-UP
 
Do not attach air  
 tools to open end 
of the hose until start-up is completed 
and the unit checks OK.
On / OFF cycLInG OF cOMPreSSOr
In the On / aUtO position, the 
compressor pumps air into the tank. 
When a shut-off (preset “cut-out”) 
pressure is reached, the compressor 
automatically shuts off.
If the compressor is left in the  
On / aUtO position and air is depleted 
from the tank by use of a tire chuck, 
tool, etc., the compressor will restart 
automatically at its preset “cut-in” 
pressure. When a tool is being used 
continuously, the compressor will cycle 
on and off automatically. 
In the OFF position, the pressure 
switch cannot function and the 
compressor will not operate. Make 
sure switch is in OFF position when 
connecting or disconnecting power 
cord from electrical outlet.
PreSSUre GaUGeS
Gauge attached to regulator indicates 
air pressure going to hose (and any 
tool attached to end of hose).
Gauge attached to pressure switch 
indicates air pressure in tank.
MOIStUre In cOMPreSSeD aIr
Moisture in compressed air will 
form into droplets as it comes 
from an air compressor pump. 
When humidity is high or when 
a compressor is in continuous use 
for an extended period of time, 
this moisture will collect in the 
tank. When using a paint spray or 
sandblast gun, this water will be 
carried from the tank through the 
hose, and out of the gun as droplets 
mixed with the spray material.
IMPOrtant: This condensation 
will cause water spots in a paint 
job, especially when spraying 
other than water based paints. If 
sandblasting, it will cause the sand 
to cake and clog the gun, rendering 
it ineffective.
A filter in the air line, located as 
near to the gun as possible, will 
help eliminate this moisture.
TEST
RESET
Figure 3 - Grounding Method
Grounded 
Outlet
Grounding 
Pin