Datalogic Scanning I GD4100 Manual Do Utilizador
Symbologies
182
Gryphon™ I GD4100
Code 39 — cont.
Code 39 Set Length 2
This feature specifies one of the barcode lengths for
Code 39 Length Control
. Length 2 is the
maximum label length if in
Variable Length
Mode, or the second fixed length if in
Fixed Length
Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length
does not include start/stop characters.
does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only
one fixed length).
one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad
the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20,
etc.
etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 39 LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in
Appendix E, Keypad
, that represent the
length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
tion after the last character.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table
22
for some examples of how to set this feature.
Table 22. Code 39 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
00 (Ignore This
Length)
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 39 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘0’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake, before the last character scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.
barcode to abort and not save the entry string. You can then start
again at the beginning.