Datalogic Scanning I GD4100 Manual Do Utilizador

Página de 324
Symbologies
214
Gryphon™ I GD4100
Interleaved 2 of 5 (I 2 of 5) — cont.
I 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for 
I 2 of 5 Length Control
. Length 2 is the 
maximum label length if in 
Variable Length
 Mode, or the second fixed length if in 
Fixed Length
Mode. The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only 
one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50, or 0 to ignore this length). The 
length must be an even number.
2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 
20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming 
Mode.
4. Scan the barcode: SELECT I 2 of 5 LENGTH 2 SETTING.
5. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that represent the 
length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mode.
This completes the procedure. See Table
28
 for some examples of how to set this feature.
Table 26. I 2 of 5 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to 
yield two digits
00
04
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From 
Appendix E, Keypad
‘0’ and ‘0’
‘0’ and ‘4’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL 
barcode to abort and not save the entry string. You can then start 
again at the beginning.