Datalogic Scanning I GD4100 Manual Do Utilizador

Página de 324
Symbologies
254
Gryphon™ I GD4100
Code 11 — cont.
Code 11 Set Length 2
This feature specifies one of the barcode lengths for 
Code 11 Length Control
. Length 2 is the 
maximum label length if in 
Variable Length
 Mode, or the second fixed length if in 
Fixed Length
Mode. Length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only 
one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50 — or 0 to ignore this length). Pad 
the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, 
etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming 
Mode.
3. Scan the barcode: SELECT CODE 11 LENGTH 2 SETTING.
4. Scan the appropriate two digits from the keypad in 
Appendix E, Keypad
, that represent the 
length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mode.
This completes the procedure. See Table
32
 for some examples of how to set this feature.
Table 32. Code 11 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting (pad with 
leading zeroes)
00 (Ignore This 
Length)
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 11 LENGTH 2 SETTING
4
Scan Two Characters From 
Appendix E, Keypad
 ‘0’ and ‘0’
‘0’ and ‘7’
‘0’ and ‘F’
‘3’ AND 2’
5
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL 
barcode to abort and not save the entry string. You can then start 
again at the beginning.