Datalogic Scanning I GD4100 Manual Do Utilizador

Página de 324
Scanning Features
Product Reference Guide
         37
Scanning Features
Scan Mode
Selects the scan operating mode for the reader. Selections are:
Trigger Single. 
When the trigger is pulled, scanning is activated until one of the following 
occurs:
-
Scanning Active Time
 has elapsed
- a label has been read
- the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is pulled, 
scanning starts and the product scans until the trigger is released, or a label is read, or the 
maximum
Scanning Active Time
 has elapsed.
Trigger Hold Multiple . 
When the trigger is pulled, scanning starts and the product scans until 
the trigger is released or 
Scanning Active Time
 has elapsed. Reading a label does not disable 
scanning. 
Double Read Timeout
 prevents undesired multiple reads of the same label while in this 
mode.
Trigger Pulse Multiple. 
When the trigger is pulled, continuous scanning is activated until 
Scanning Active Time
 has elapsed or the trigger has been released and pulled again. 
Double Read 
Timeout
1 prevents undesired multiple reads of the same label while in this mode.
Flashing. 
The reader flashes
1
 on and off regardless of the trigger status. Flash rate is controlled 
by 
Flash On Time
 and 
Flash Off Time
. When Flash is ON the imager reads continuously; when 
Flash is OFF scanning is deactivated. 
Always On. 
No trigger pull is required to read a barcode. Scanning is continually on. If the 
trigger is pulled, the reader acts as if it is in 
Trigger Single
 Mode. 
Double Read Timeout
1 prevents 
undesired multiple reads of the same label while in this mode.
Stand Mode. 
No trigger pull is required to read a barcode. Scanning is turned on automatically 
when an item is placed in the reader’s field of view. If the trigger is pulled, the reader acts as if it 
in single read mode. 
Double Read Timeout
1 prevents undesired multiple reads while in this 
mode.
Trigger Object Sense. 
This mode is similar to Stand Mode, except that a trigger pull is required 
to activate the decoder.
1. Controlled by 
Flash On Time
.