Datalogic Scanning I GD4100 Manual Do Utilizador

Página de 324
RS-232/USB-Com Interfaces
64
Gryphon™ I GD4100
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII 
characters or any hex value from 0 to 0xFF can be selected.
NOTE
To set this feature:
1. Determine the desired character or value.
2. Use the 
ASCII Chart
 on the inside back cover of this manual to find the hex equivalent for 
the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming 
Mode.
4. Scan the barcode: SELECT ACK CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in 
Appendix E, Key-
pad
, that represent the desired character/value in step 1 above. The second character will 
cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming 
Mode.
This completes the procedure. See Table
8
 for some examples of how to set this feature.
Table 8. ACK Character Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Character/Value
ACK
$
@
>
2
Hex equivalent
0x06
 0x24
0x40
0x3E
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK CHARACTER SETTING
5
Scan Two Characters From 
Appendix E, Keypad
‘0’ and ‘6’
‘2’ and ‘4’
‘4’ and ‘0’
‘3’ AND ‘E’
6
Scan ENTER/EXIT PROGRAMMING MODE
Setting to previously defined characters such as XON, XOFF, 
or host commands conflicts with normal operation of these 
characters. 8-bit data is not recognized when the option 
Data 
Bits
 has been set as 7 Data Bits.