                       5K320 SATA OEM Specification 
105 
 
14.12  Initialize Device Parameters (91h)   
Command Block Output Registers 
   Command Block Input Registers 
Register 
7  6  5  4  3  2  1  0     Register 
7  6  5  4  3  2  1  0 
Data 
-  -  -  - 
-  -  -     Data 
-  -  -  -  -  -  - 
Feature 
-  -  -  - 
-  -  -     Error 
...See Below... 
Sector Count 
V  V  V  V  V  V  V  V     Sector Count 
-  -  -  -  -  -  - 
LBA Low  
-  -  -  - 
-  -  -     LBA Low  
-  -  -  -  -  -  - 
LBA Mid 
-  -  -  - 
-  -  -     LBA Mid 
-  -  -  -  -  -  - 
LBA High 
-  -  -  - 
-  -  -     LBA High 
-  -  -  -  -  -  - 
Device 
-  -  -  H   H   H  H     Device 
-  -  -  -  -  -  - 
Command 
1  0  0  1  0  0  0  1     Status 
...See Below... 
 
Error Register 
  
Status Register 
  
CRC  UNC 
IDN 
ABT   T0N 
AM
   BSY  RDY 
DF 
DSC  DRQ   COR  IDX  ERR 
  
Table  67 Initialize Device Parameters Command (91h)   
The Initialize Device Parameters command enables the host to set the number of sectors per track 
and the number of heads minus 1, per cylinder. Words 54-58 in Identify Device Information reflects 
these parameters.   
The parameters remain in effect until the following events:   
l  Another Initialize Device Parameters command is received.  
l  The device is powered off.   
l  Soft reset occurs and the Set Feature option of CCh is set  
Output Parameters To The Device  
Sector Count 
The number of sectors p er track. 0 does not mean there are 256 sectors per track, but there is no 
sector per track. 