14.34  Sense Condition (F0h : vendor specific)   
Command Block Output Registers 
   Command Block Input Registers 
Register 
7  6  5  4  3  2  1  0     Register 
7  6  5  4  3  2  1  0 
Data 
-  -  -  - 
-  -  -     Data 
-  -  -  -  -  -  - 
Feature 
0  0  0  0  0  0  0  1     Error 
...See Below... 
Sector Count 
-  -  -  - 
-  -  -     Sector Count 
V  V  V  V  V  V  V  V 
LBA Low  
-  -  -  - 
-  -  -     LBA Low  
-  -  -  -  -  -  N 
LBA Mid 
-  -  -  - 
-  -  -     LBA Mid 
-  -  -  -  -  -  - 
LBA High 
-  -  -  - 
-  -  -     LBA High 
-  -  -  -  -  -  - 
Device 
-  -  -  - 
-  -  -     Device 
-  -  -  -  -  -  - 
Command 
1  1  1  1  0  0  0  0     Status 
...See Below... 
 
Error Register 
  
Status Register 
  
CRC  UNC 
IDN 
ABT   T0N 
AM
   BSY  RDY 
DF 
DSC  DRQ   COR  IDX  ERR 
  
Table  104 Sense Condition Command (F0h)   
The Sense Condition command is used to sense temperature in a device.   
This command is executable without spinning up even if a device is started with No Spin Up option.   
If this command is issued at the temperature out of range which is specified for operating condition, 
the error might be returned with IDN bit 1.   
Output Parameters To The Device  
Feature 
The Feature register must be set to 01h. All other value are rejected with 
setting ABORT bit in status register. 
Input Parameters From The Device 
Sector Count 
The Sector Count register contains result value. 
 
Value 
Description 
 
00h 
Temperature is equal to or lower than -20 degC 
 
01h-FEh 
Temperature is (Value / 2 - 20) deg C 
 
FFh 
Temperature is higher than 107 degC  
N 
Not recommendable condition for start up. If over stressed condition is 
detected, this bit will be set to one.