Fujitsu MBA3147RC Manual Do Utilizador

Página de 439
 
1.4   Link layer 
 
C141-C013 
53 
4)  When, in contradiction to the fact that the physical link rate is 1.5 Gbps, the 
CONNECTION RATE field in a received OPEN frame is 3.0G, the drive 
sends the OPEN_REJECT (CONNECTION RATE NOT SUPPORTED) 
primitive. 
5)  A dual port drive may process requests from up to four INITs at a time for 
each port.  When a dual port drive holds commands from four INITs for one 
of its ports, and if it receives a connection request from a fifth INIT through 
the same port, the drive sends the OPEN_REJECT (RETRY) primitive. 
6)  When the drive cannot receive an SSP frame temporarily due to the recovery 
processing of an internal drive error, the drive sends the OPEN_REJECT 
(RETRY) primitive. 
7)  When the SAS address of a drive does not match the DESTINATION SAS 
ADDRESS field in a received OPEN frame, the drive sends the 
OPEN_REJECT (WRONG DESTINATION) primitive. 
 
1.4.3.12  SOAF (Start of address frame)  
SOAF specifies the start of an address frame.