Fujitsu MCF3064AP Manual Do Utilizador
4 - 32
C156-E142-02EN
4.5.8
NOP (X'00')
Table 4.30 NOP command
Bit
7
6
5
4
3
2
1
0
CM
0
0
0
0
0
0
0
0
DH
X
X
X
DRV
X
X
X
X
CH
X
X
X
X
X
X
X
X
CL
X
X
X
X
X
X
X
X
SN
X
X
X
X
X
X
X
X
SC
X
X
X
X
X
X
X
X
FR
X
X
X
X
X
X
X
X
The NOP command enables 16-bit access for Status register checking. The ODD judges an
unsupported command. The command ends with Aborted Command.
unsupported command. The command ends with Aborted Command.
4.5.9
SERVICE (X'A2') (Not supported)
Table 4.31 SERVICE command
Bit
7
6
5
4
3
2
1
0
CM
1
0
1
0
0
0
1
0
DH
X
X
X
DRV
X
X
X
X
CH
X
X
X
X
X
X
X
X
CL
X
X
X
X
X
X
X
X
SN
X
X
X
X
X
X
X
X
SC
X
X
X
X
X
X
X
X
FR
X
X
X
X
X
X
X
X