Fujitsu MCF3064AP Manual Do Utilizador

Página de 175
3 - 4
C156-E142-02EN
Note:
Air flow temperature is 40°C and below.
3.1.4
Temperature rise under several conditions
Table 3.2
Temperature at each measuring point (Reference)
[Ambient atmospheric temperature of the optical disk drive:  45°C]        (°C)
Measurement point
Ready
Random seek
Criteria
Inside cartridge
49°C
54°C
55°C
IC (controller) surface
50°C
70°C
95°C
IC (read amp.) surface
48°C
70°C
85°C
Thermal sensor
47°C
55°C
Notes:
1.  The above data are data measured in a constant temperature chamber in which the
temperature surrounding the equipment was kept at 45°C. They are not the same as the
data obtained from measurements using the exclusive box in which the equipment is
normally used.
2.
When using the box, the ambient temperature around the equipment will differ depending
on the air circulation conditions of the box, and the temperature rise inside the cartridge
will differ because of this, so please exercise caution.
3.1.5
Air purity
Air purity in the device environment is expressed by the number of dust particles per unit area and
must be class 5 millions (equivalent to 0.15 mg/m
3
) or less.  (Class 500 millions:  500 millions dust
particles of 0.5 
!m dia. or larger per cubic foot)