Fujitsu MBC2073RC Manual Do Utilizador
Parameter Data Format
5.1.7 Control Mode Parameters (Page Code = 0A)
The page descriptor format of this MODE SELECT parameter is shown in Table
5.9.
5.9.
Table 5.9 MODE SELECT parameters: control mode parameters
Bit
Byte
Byte
7 6 5 4 3 2 1 0
0
0 0 0 0 1 0 1 0
1
X'0A' (Page Length)
2 TST
(Reserved)
GLTSD
RLEC
Default 0 0 0 0 0 0 0 0
Variable 0 0 0 0 0 0 1 1
3
Queue Algorithm Qualifier
Reserved
Qerr
DQue
Default 0 0 0 0 0 0 0 0
Variable 1 1 1 1 0 1 1 1
4 VS
RAC
Reserved
SWP
Reserved
Default 0 0 0 0 0 0 0 0
Variable 0 0 0 0 0 0 0 0
5
Reserved
TAS Reserved AUTOLOAD
MODE
Default 0 0 0 0 0 0 0 0
Variable 0 0 0 0 0 0 0 0
6-7 X'000'
(Reserved)
8-9
Busy Timeout Period
Default
X'0000'
Variable
X'0000'
10-11
Extended Self-Test Completion Time
Default
X'xxxx'
Variable
X'0000'
The parameters defined on this page control the operations of the tagged queuing
function and statistical information function.
function and statistical information function.
304