Fujitsu MBC2073RC Manual Do Utilizador

Página de 439
 
5.1  Mode Parameters 
If "1" is specified, the HDD is permitted to enter the Standby condition after 
the elapse of the time specified in the "Standby Condition Timer" field. 
If "0" is specified, the HDD is prohibited from entering the Standby condition. 
d.  Standby Condition Timer (unsupported) 
Specifies the time before the HDD enters the Standby condition.  When the 
Standby bit is "1," the HDD enters the Standby condition after the elapse of 
the time calculated by multiplying the value specified in this field by 100 ms. 
 
5.1.11  Informational Exceptions Control Page (Page Code = 1C)  
Table 5.15  MODE SELECT parameters:  informational exception control page 
 Bit 
Byte 
7 6 5 4 3 2 1 0 
0 0 0 1 1 1 0 0 
Page length (X'0A') 
2 Perf 
EBF 
EWASC
DExcpt
Test 
EBACKERR 
LogErr
 Default 0 0 0 0 0 0 0 1 
 
Variable 1 0 1 1 1 1 1 1 
0 0 0 0 
MRIE 
 Default 0 0 0 0 0 0 0 0 
 
Variable 0 0 0 0 0 1 1 1 
4-7 Interval 
Time 
 Default 
X'00000000' 
 Variable 
X'FFFFFFFF' 
8-11 Report 
Count 
 Default 
X'00000001' 
 Variable 
X'FFFFFFFF' 
 
This page specifies whether the drive failure prediction function is enabled or 
disabled and the reporting method when a drive failure is predicted. 
a.  LogErr (log error)  
This bit (LogErr) of zero indicates that the logging of informational exception 
conditions within a target is vendor specific.  A LogErr bit of one indicates 
the target logs informational exception conditions. 
b.  EBF (enable background function)  
If background functions are supported, this bit of one indicates the target 
enables background functions.  An "EBF" bit of zero indicates the target 
disables the functions. 
c.  EWASC (enable warning)  
C141-C013 
317