Fujitsu MBC2073RC Manual Do Utilizador

Página de 439
 
5.1  Mode Parameters 
5.1.13  Additional Error Recovery Parameters (Page Code = 21)  
The page descriptor format of this MODE SELECT parameter is shown in Table 
5.19. 
Table 5.19  MODE SELECT parameters:  additional error recovery parameters 
[Fujitsu unique parameter] 
 Bit 
Byte 
7 6 5 4 3 2 1 0 
0 0 
X'02' (Page Length) 
Number of retries during a Seek Error
 Default  0 0 0 0 1 1 1 1 
 
Variable  0 0 0 0 1 1 1 1 
3 RFJ 
 Default  0 0 0 0 0 0 0 0 
 
Variable 0 0 0 0 0 0 0 0 
 
a.  Number of retries during a seek error 
This parameter specifies the number of times repositioning is retried when a 
seek error is detected.  When zero is specified in this field, repositioning 
retries are prohibited.  The value specified in this field is applicable for all 
commands which are accompanied by a seek operation. 
b.  RFJ (reserved by Fujitsu)  
All the bits in byte 3 are reserved by Fujitsu.  The user should specify "0" in 
this bit. 
 
C141-C013 